TROUBLESHOOTING
20 Residenal Hybrid Electric Heat Pump Water Heater Use and Care Guide
 INDICATES CORRECTIVE ACTION
 Unit is doing a system
diagnostic.
Normal operation--no action
ICE Heat pump is in defrosting
cycle.
HPO Ambient temperature <45°F
or >120°F, average tank
temperature of 59°F or less.
*
EUC Upper element is not
functioning
Refer to Page 22, Step 2 “Check Upper Heating Element.” and
Page 27 “Replacing the Heating Element”
ELC Lower element is not
functioning
Refer to Page 22, Step 2 “Check Upper Heating Element.” and
Page 27 “Replacing the Heating Element”
SF The air filter is dirty. Refer to “Air Filter Maintenance” page 30.
*
ECF The heat pump compressor is
starting/stopping frequently.
1. If compressor is running and fan is not operating, call
residential technical support.
2. Clean the air filter. See “Air Filter Maintenance” section
on page 30.
3. Check installation location against recommended
confined space requirements (step 2, page 9).
*
 Upper Temperature Sensor is
not functioning.
Power off (Power Cycling the unit, page 25), disconnect and
reconnect J2 and J5 connections from control board, inspect
wire for damage, re-install UIM, reconnect power. If error
persists, replace temperature sensor.
 Lower Temperature Sensor is not
functioning.
 Heat Pump Suction Temperature
Sensor is not functioning.
 Heat Pump Coil Temperature
Sensor is not functioning.
 Heat Pump Discharge
Temperature Sensor is not
functioning.
*
E60 Upper and Lower Temperature
Sensor are not functioning
*
Edr Not enough water in the tank
(tank not full).
Open all hot water taps in home and run until water
(uninterrupted) flows from all open hot water taps.
EPL Power supply voltage is too low. Check for loose electrical connections, refer to “Power
Cycling the Unit”, page 25
*
EDH Compressor Discharge
Temperature is too high.
Call Residential Technical Support
 The diagnostic codes listed above are the most common. If a diagnostic code not listed above is displayed, contact Residential
Technical Support referencing the number on the front of this manual.
* There may be an audible alarm associated with this error. To cancel the audible alarm, press any buon on the UIM.
DIAGNOSTIC CODES



Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the A.O. Smith ProLine XE and is the answer not in the manual?

A.O. Smith ProLine XE Specifications

General IconGeneral
CategoryWater Heater
BrandA.O. Smith
ModelProLine XE
Installation LocationIndoor
Energy Factor0.95
Vent TypeDirect Vent
Voltage240V
Warranty6 years
Capacity40 - 100 gallons

Related product manuals