Parameter Specifications
Wire size for the terminal block plug (rec-
ommended)
24 AWG (0.5 mm
2
) minimum
Required torque 0.5 Nm
Strip length 5 mm
Terminal connections
• PE/Shield: Contact input terminal 1 or 2
• Configuration input: Contact input ter-
minal 2 or 1
Wire AWG and cross section: based on a copper wire type
11.13.6 Dry contacts output
The dry contacts input is the single contact in the EVSE.
Parameter Specifications
EVSE connector type Terminal block plug and screws
Wire size for the terminal block plug (al-
lowed maximum)
• 2.5 - 0.5 mm
2
(Europe)
• 12 - 30 AWG (North America)
Wire size for the terminal block plug (rec-
ommended)
20 AWG (0.75 mm
2
) minimum
Required torque 0.5 Nm
Strip length 5 mm
Terminal connections
• Configuration output dry contact 1:
Contact output terminal 1
• Configuration output dry contact 2:
Contact output terminal 2
Contact rated load 125 VAC/30VDC at 3A
The wire AWG and cross section are based on a copper wire type.
11.13.7 EV charge cable specifications
Parameter Value [mm]
Length 508
11.14 AC output specifications
11.14.1 AC output specifications (Europe)
Parameter Specification
AC output voltage range (1 phase) 220 - 240V AC
AC output voltage range (3 phase) 380 - 415V AC
Technical data
56 BCM.V3Y01.0-EN | 001