Page #4 background imageLoading...
Page #4 background image
V-3010 02 070424 GB
Alde International Systems AB
Wrangels allé 90 • Box 11066 • S-291 11 Färlöv • Sweden
Tel +46 (0)44 712 70 • Fax +46 (0)44 718 48 • www.alde.se • info@alde.se
Working with the lower menu row, see operating/installation instruction
for Compact 3010
The lower menu row can be used for such things as setting the clock, external start, night temperature, automatic
start of the heater.
8. Circulation pump
This symbol is displayed when the circulation pump is operating (12V-
pump or 230V-pump).
When heating is required in the vehicle, the pump starts automatically.
The boiler selects the 230V pump if one is installed in the system. When
the 230V is disconnected from the vehicle the 12V pump is automatically
selected. The symbol will light up even if the pump is defective.
9. 230V connection
This symbol lights up when 230V is connected to the
vehicle.
10. Temperature
This symbol shows the indoor temperature
in the caravan in intervals of 0.5°C.
This symbol shows the temperature outside the
caravan in intervals of 1°C. To use this function an
outdoor temperature sensor must be installed.
11. Resetting the system
1 Press the Store/Reset button for
10 seconds. The control panel is
reset to the factory setting.
2 The main breaker to the control
panel is in the “Off” position,
Gas is on, Electricity at 1kW and
22°C.
The pump is in automatic
position. The lower menu row is
not lit up.

Other manuals for Alde Compact 3010

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Alde Compact 3010 and is the answer not in the manual?

Alde Compact 3010 Specifications

General IconGeneral
BrandAlde
ModelCompact 3010
CategoryBoiler
LanguageEnglish

Related product manuals