Process Point:
ALLEN&HEATH
Programming
AH-M0264
Assembly data
Production line iLiveSeries
Product ilive SBC Fujitsu 004-111
Assembly stage Programming
Issue Date 22/07/11
8 Use the arrows keys to move across the menu bar and select Main.
9 Select Boot features
10 Check/Change the Keyboard Check to [Disable]
11 Now press Esc to go back to the Main page
12 Use the arrows keys to move across the menu bar and select Advanced
13 Select Peripheral Configuration
14 Select LCD parameter and select [800 x 600 6Bit single]
15 Now press Esc to go back to the Advanced page.
16 Use the arrows keys to move across the menu bar and select Security.
17 Select Change Supervisor Password
18 You need to enter the password “Digital” twice and Enter to confirm.
19 Use the arrows keys to move across the menu bar and select Power
20 Select Power Fail Recovery and Select [Always On]
21 Use the arrows keys to move across the menu bar and select Boot
22 Move [IDEO: STEC M2 + CF 9.0.2 – (pm)] to the 1 position. This is done by using the + key
to move it to the 1
st
position. If it is not on the list you need to highlighting it and by using x you can
include it on to the list.
23 Go to Exit and select Save Changes and Exit
24 Press enter to Save configuration changes and exit set-up
25 Reboot the SBC to see if the SBC can boot to the connect
screen
26 Power down and disconnect
27 Fit the Flash card holder as shown on the right
28 Put SBC back into the bag and place on the program shelf
Page 2/2