The compressor is automatically controlled and may be restarted automatically.
Initial start procedure
If the compressor has not run for the past 6 months, it is strongly recommended to
improve the lubrication of the compressor element before starting.
To do so:
1. Disconnect the inlet hose.
2. Remove the unloader (UA).
3. Pour approximately 0.75 l (0.20 US gal, 0.17 Imp gal) of compressor oil into the
compressor element inlet. For oil specifications, see section Oil specifications.
4. Reinstall the unloader and reconnect the inlet hose.
Make sure that all connections are tight.
Location of unloader
1. Check the oil level before starting.
The oil level should be between the oil filler neck (FC) and the bottom of the sight glass (Gl).
Instruction book
2920 7180 30 141

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Atlas Copco GA 30+ and is the answer not in the manual?

Atlas Copco GA 30+ Specifications

General IconGeneral
ModelGA 30+
CategoryAir Compressor
Power30 kW
Working Pressure7.5-13 bar
Cooling SystemAir-cooled
Noise Level69 dB(A)
FAD5.2 m³/min