Installation
EN
88 bora.com
1
2
3
4
5
6
7
Fig.8.12
Water drainage via hook
[1]
Waste water siphon
[2]
Water outlet hose
[3]
Water supply hose
[4]
Fresh water connection
[5]
Waste water connection
[6]
Bore hole for installation
[7]
Hook
8.6.4
Fresh and waste water
connection
u
Check whether there is a washer in each threaded
coupling on the water supply hose. If necessary, fit a
washer.
u
Screw the angled end of the water supply hose to the
fresh water connection on the appliance. The angled
end must be facing downwards.
u
Check that it is screwed on tight and is firmly in place.
u
Using the hose clip, attach the angled end of the
water outlet hose to the waste water connection on
the appliance. The angled end must be facing
downwards. If the XBOMSU installation set is
required, the angled end must be facing upwards.
The hose clip must only be attached hand-tight.
u
Check that the hose clip is firmly in place.
u
Ensure that there are no kinks in the hoses.
u
Slowly open the stopcock for the fresh water supply
and check that the fresh water connection is tightly
sealed. If necessary, check that the washer and
screw connections are firmly in place.
8.6.5
Power supply
u
Observe all safety and warning information
(see"2Safety").
u
Observe all national and regional laws and
regulations as well as the supplementary regulations
of the local utility companies.
The appliances may only be connected to the
mains power supply by certified specialists. The
specialist also assumes responsibility for the
proper installation and commissioning.
Connections via plug-in contacts (Schuko plugs)
are not permitted.
1-phase connection. The appliance complies
with the requirements of IEC 61000-3-12.
T
This appliance is intended to be operated on a supply
network with an impedance Zmax at the transfer
point (mains connection) of 0.0416 ohms maximum.
The user is to ensure that the appliance is only
operated on a mains supply network which meets
this requirement. If necessary, ask the local energy
supply company about the system impedance.
u
Switch off the main switch/automatic circuit breaker
before connecting the appliance.
u
Secure the main switch/automatic circuit breaker
against being switched back on without permission.
u
Make sure the power to the appliance is disconnected.
u
Connect the appliance exclusively via a fixed
connection to a mains supply cable type H 05 VV-F
with corresponding minimum cross-section.
Connection 2-phase
connection
1-phase
connection
Fuse protection
2 x 16A 1 x 16A
Maximum power
consumption
6100 W 3600 W
Minimum
cross-section
2.5 mm
2
2.5 mm
2
Tab.8.2
Fuse protection and minimum cross-section
u
Connect the power supply cable to the power supply
of the appliance in accordance with the relevant
connection diagram.
u
Secure the power supply cable with the strain relief
clamp.
u
Close the power supply housing cover.
u
Check that installation has been carried out correctly.