KIT CONTENTS
ITEM PART NO. QTY. DESCRIPTION
1 12422.0001 1 Clamp, Hose-Snap Type
2 05749.0004 1 Plug, Hole Black .50”
3 29279.0000 1 Cap, Tube-Silicone
INSTRUCTIONS
FAUCET REMOVAL MUST BE PERFORMED BY AUTHORIZED SERVICE PERSONNEL
ONLY!
WARNING: Disconnect brewer from power source before the removal of any panel or
replacement of any component.
WARNING: Water drained from the brewer and many internal parts are extremely
hot; allow contents of tank to cool before proceeding.
1. Remove the front access panel and top cover to gain access to the drain tube and
faucet tube. (FIG. 1)
2. Locate the end of the drain tube hose in the base of the brewer and pull it out.
(FIG. 2)
NOTE: If the brewer has been in service, the tank must be drained before proceeding.
CAUTION
DISCARD DECANTER
IF:
. CRACKED
. SCRATCHED
. BOILED DRY
. HEATED WHEN EMPTY
. USED ON HIGH FLAME
. OR EXPOSED ELECTRIC
ELEMENTS
FAILURE TO COMPLY RISKS INJURY
PN: 6
58
1985 BUNN-O-MATIC CORPORATION
FUNNEL CONTENTS
ARE HOT
!
BUNN-O-MATIC CORPORATION
POST OFFICE BOX 3227
SPRINGFIELD, ILLINOIS 62708-3227
PHONE: (217) 529-6601 FAX: (217) 529-6644
44859.0000A 04/11 ©2011 Bunn-O-Matic Corporation
DUAL SH DBC/
SINGLE SH DBC
CAUTION
DISCARD DECANTER
IF:
. CRACKED
. SCRATCHED
. BOILED DRY
. HEATED WHEN EMPTY
. USED ON HIGH FLAME
. OR EXPOSED ELECTRIC
ELEMENTS
FAILURE TO COMPLY RISKS INJURY
PN: 658
1985 BUNN-O-MATIC CORPORATION
FUNNEL CONTENTS
ARE HOT
!
FIG 2
FAUCET REMOVAL
INSTRUCTIONS
Top Cover
Access
Panel
Drain Tube
Pinch Valve
Clamp
Plug
INTRODUCTION
This kit is intended for use on all DUAL SH DBC
®
and SINGLE SH DBC
®
models with the Hi-Lime tank. The
upper hot water faucet on the brewers can be removed using this kit.
FIG 1