3. THERMOSTAT CAREL IR33W- SET PARAMETERS FRIDGE CABINETS
1
4. Press “Set (4) to view or change the values within parameter code.
5. Use the “UP and “Down arrow keys (3) 5) to increase or decrease value of parameter code.
6. Once you have required value press
Set (4) to save.
7. Repeat steps 3 to 6 to set other parameters. The icons shown on the display correspond to the
category of parameter (see table below).
8. To permanently save the values and exit, press “Prg/mute and hold for more than 5 seconds.
OPERATING INSTRUCTIONS CAREL IR33 (G60875, G60890)
AS A THERMOMETER ONLY
:
1
2 3
4
5
2 3
4 5
Carel ir33 Control Keys Display
ENGINEER ONLY SETTINGS, PLEASE READ AND UNDERSTAND FULLY BEFORE PROCEEDING
Factory Reset (only required if parameters in table below have been unknowingly changed)
1. To set default parameter values switch off instrument.
2. Switch back on, hold “
Prg/ mute key (2) until the message “Std is shown on the display.
How to change the SET PARAMETERS
1. To access the set parameter codes- press and hold Prg / mute (2) & Set(4) keys together for 5
seconds. The display will show “00”.
2. Press the UParrow key (3) until you reach value 2 2 and then press Set (4) to confirm (you will
now be in the configuration parameters)
3. Use the “UP and “Down arrow keys (3) (5) to change between parameter codes (see table on next
page for codes).
TO SET THE IR33 AS A TEMPERATURE DISPLAY ONLY (Thermometer)
1. Compressor ON
2. Key Prg/ mute
3. Key UP
4. Key Set
5. Key DOWN