58VMR
Multipoise
Oil Furnace
Installation, Start-Up, and Operating Instructions
For Input Capacities of 70,000—154,000; Series 110
NOTE: Read the entire instruction manual before starting the
installation.
TABLE OF CONTENTS
SAFETY CONDSIDERATIONS ..................................................1
INTRODUCTION..........................................................................2
LOCATION....................................................................................3
General ......................................................................................3
Location Relative to Cooling Equipment ................................3
INSTALLATION...........................................................................4
Air for Combustion and Ventilation ........................................4
General ......................................................................................4
Unconfined Space.....................................................................4
Confined Space.........................................................................5
All Air from Inside the Structure .......................................5
All Air from Outside of Structure ......................................5
Duct Work Recommendations ............................................5
Venting .................................................................................6
Oil Burner............................................................................6
Oil Connections...................................................................6
Barometric Draft Control ....................................................7
Electrical Connections.........................................................7
Filters ...................................................................................7
Horizontal or Downflow Installation..................................7
START-UP, ADJUSTMENT, AND SAFETY CHECKOUT....10
Operational Checkout .............................................................10
Combustion Check..................................................................10
Fan Adjustment Check ...........................................................12
Limit Control Check...............................................................12
For Year-Round Air Conditioning.........................................12
Heating ....................................................................................12
Cooling....................................................................................12
MAINTENANCE.........................................................................12
General ....................................................................................13
Oil Burner ...............................................................................14
Heat Exchanger and Flue Pipe...............................................15
Blower Removal .....................................................................15
SAFETY CONDSIDERATIONS
FOR YOUR SAFETY
DO NOT STORE OR USE GASOLINE OR OTHER
FLAMMABLE VAPORS AND LIQUIDS IN THE VI-
CINITY OF THIS OR ANY OTHER APPLIANCE.
DO NOT ATTEMPT TO START THE BURNER
WHEN EXCESS OIL HAS ACCUMULATED, WHEN
THE FURNACE IS FULL OF VAPOR, OR WHEN
THE COMBUSTION CHAMBER IS VERY HOT.
CARBON MONOXIDE POISONING, FIRE,
EXPLOSION HAZARD
Failure to follow this warning could lead to sooting, fire,
explosion, and/or severe bodily harm.
For use with grade 1 or 2 fuel oil. Do not use gasoline,
crankcase oil, or any oil containing gasoline!
FIRE HAZARD
Failure to follow this caution may result in fire and property
damage.
Never burn garbage or paper in the heating system and never
leave rags, paper, or any flammable items around the unit.
UNIT RELIABILITY HAZARD
These instructions are intended to be used by qualified
personnel who have been trained in installing this type of
furnace. Installation of this furnace by an unqualified person
may lead to equipment damage and/or a hazardous condition
which may lead to bodily harm.
Fig. 1—58VMR Multipoise Oil Furnace
A97247
Visit www.carrier.com
Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.
Book 1 4
Tab 6a 8a
PC 101 Catalog No. 535-80152 Printed in U.S.A. Form 58VMR-1SI Pg 1 10-04 Replaces: NEW

Other manuals for Carrier 110 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Carrier 110 Series and is the answer not in the manual?

Carrier 110 Series Specifications

General IconGeneral
BrandCarrier
Model110 Series
CategoryFurnace
LanguageEnglish

Related product manuals