Page #1 background image
58PAV, 58RAV
Induced-Combustion Furnaces
Service and Maintenance Instructions
For Sizes 045-155, Series 170 and 180
NOTE: Read the entire instruction manual before performing any
service or maintenance.
This symbol indicates a change since the last issue.
These procedures are for size 44,000 through 154,000 Btuh input
units.
Index Page
SAFETY CONSIDERATIONS..................................................1-2
ELECTROSTATIC DISCHARGE (ESD) PRECAUTIONS
PROCEDURE...........................................................................2
CARE AND MAINTENANCE................................................2-11
Air Filter Arrangement..........................................................2-3
Blower Motor and Wheel......................................................3-5
Cleaning Heat Exchanger......................................................5-6
Electrical Controls and Wiring .............................................6-7
Troubleshooting...................................................................7-13
Unit Wiring Diagram................................................................9
Service Label ..........................................................................10
Troubleshooting Guide......................................................10-13
SAFETY CONSIDERATIONS
Installing and servicing heating equipment can be hazardous due to
gas and electrical components. Only trained and qualified person-
nel should install, repair, or service heating equipment.
Untrained personnel can perform basic maintenance functions
such as cleaning and replacing air filters. All other operations must
be performed by trained service personnel. When working on
heating equipment, observe precautions in the literature, on tags,
and on labels attached to or shipped with the unit and other safety
precautions that may apply.
Follow all safety codes. In the United States, follow all safety
codes including the National Fuel Gas Code (NFGC) NFPA
54-1999/ANSI Z223.1-1999 NFPA 90B. In Canada, refer to the
CAN/CGA-B149.1- and .2-M95 National Standard of Canada,
Natural Gas and Propane Installation Codes (NSCNGPIC). Wear
safety glasses and work gloves. Have fire extinguisher available
during start-up and adjustment procedures and service calls.
Recognize safety information. This is the safety-alert symbol
.
When you see this symbol on the furnace and in instructions or
manuals, be alert to the potential for personal injury.
Understand the signal words DANGER, WARNING, CAUTION,
and NOTE. These words are used with the safety-alert symbol.
DANGER identifies the most serious hazards which will result in
severe personal injury or death. WARNING signifies a hazard
which could result in personal injury or death. CAUTION is used
to identify unsafe practices which would result in minor personal
injury or product and property damage. NOTE is used to highlight
suggestions which will result in enhanced installation, reliability,
or operation.
Fig. 3—Model 58PAV
Upflow
A94085
Fig. 2—Model 58RAV
Downflow
A94086
Fig. 1—Model 58RAV Horizontal
A94087
ama
CERTIFIED
REGISTERED
QUALITY SYSTEM
Visit www.carrier.com
Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.
Book 1 4
Tab 6a 8a
PC 101 Catalog No. 535-773 Printed in U.S.A. Form 58P,R-15SM Pg 1 10-00 Replaces: 58P,R-14SM

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Carrier 170 Series and is the answer not in the manual?

Carrier 170 Series Specifications

General IconGeneral
BrandCarrier
Model170 Series
CategoryFurnace
LanguageEnglish

Related product manuals