Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.
Catalog No. 04-53450004-01 Printed in U.S.A. Form 45-6SI Pg 1 12-22 Replaces: 45-5SI
Installation, Start-Up and
Service Instructions
CONTENTS
Page
SAFETY CONSIDERATIONS . . . . . . . . . . . . . . . . . . . 1
PRE-INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . 2
General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
CONTROL OFFERINGS
STORAGE AND HANDLING
INITIAL INSPECTION
Unit Identification . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
INSTALLATION PRECAUTION
SERVICE ACCESS
CODES
UNIT SUSPENSION
Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
CONTROL OPTIONS
VAV CCN Controls and OPEN VAV Controls . . . . . . 4
VVT CCN Controls and OPEN VVT Controls . . . . . . 4
Analog Electronic Controls . . . . . . . . . . . . . . . . . . . . 4
Pneumatic Controls . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Direct Digital Controls (By Others) . . . . . . . . . . . . . . 4
No Control Units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Step 1 — Install Fan-Powered Box . . . . . . . . . . . . . . 4
SELECT LOCATION
POSITION UNIT
INSTALL UNIT
Step 2 — Make Duct Connections . . . . . . . . . . . . . . . 5
Step 3 — Connect Power Wiring . . . . . . . . . . . . . . . . 5
Step 4 — Set Up System and Calibrate . . . . . . . . . . . 7
GENERAL
SET POINTS
SYSTEM CALIBRATION OF THE INLET AIRFLOW
SENSOR
START-UP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Initial Start-Up Procedures . . . . . . . . . . . . . . . . . . . . . 8
Balancing Carrier Fan Terminals . . . . . . . . . . . . . . . . 9
45J,K,Q SERIES FLOW UNITS
BALANCING 45M,N,R PARALLEL FLOW UNITS
Speed Controller . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Setting Fan Air Flow with ECM Motors . . . . . . . . . . 17
VCU (CONTROL OPTION 6)
ACU-O, 0-10VDC (0-20MA) INPUT
(CONTROL OPTION 7)
ACU-P, 2-10VDC (4-20MA) INPUT (CONTROL
OPTION 8)
General — Single Function Pneumatic Controller
Control Sequences (1300-1305, 1400-1401) . . . . 33
Units with Single-Function Controllers . . . . . . . . . .33
Units with Multi-Function Controllers (Sequences
1306-1317 and 1402-1405) . . . . . . . . . . . . . . . . . . .34
Operation Sequences . . . . . . . . . . . . . . . . . . . . . . . .34
Analog Controls Installation and Balancing
Procedures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .35
Thermostat Installation . . . . . . . . . . . . . . . . . . . . . . .35
Programming Thermostat . . . . . . . . . . . . . . . . . . . . .36
Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .37
Fan Motor and Wheel . . . . . . . . . . . . . . . . . . . . . . . . .37
TO CHECK WIRING
TROUBLESHOOTING
Fan Motor Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . .37
Fan Motor Maintenance . . . . . . . . . . . . . . . . . . . . . . .37
SAFETY CONSIDERATIONS
See Fig. 1 for the Proposition 65 warning label.
Fig. 1 — Proposition 65 Warning Label
IMPORTANT: Air-handling equipment will provide safe
and reliable service when operated within design specifica-
tions. The equipment should be operated and serviced only
by authorized personnel who have a thorough knowledge of
system operation, safety devices, and emergency proce-
dures. Good judgment should be used in applying any man-
ufacturer’s instructions to avoid injury to personnel or
damage to equipment and property.
WARNING
Disconnect all power to the unit before performing mainte-
nance or service. Unit may automatically start if power is not
disconnected. Electrical shock and personal injury could result.
WARNING
If it is necessary to remove and dispose of mercury contactors
in electric heat section, follow all local, state, and federal
laws regarding disposal of equipment containing hazardous
materials.
!
WARNING: Cancer - www.P65Warnings.ca.gov
45J,K,M,N,Q,R
Fan Powered
Variable Air Volume Terminals

Questions and Answers: