Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.
Catalog No. 04-53500302-01 Printed in U.S.A. Form 50FC-20-30-01SM Pg 1 1-24 Replaces: NEW
Service and Maintenance Instructions
CONTENTS
Page
SAFETY CONSIDERATIONS . . . . . . . . . . . . . . . . . . . 2
UNIT ARRANGEMENT AND ACCESS . . . . . . . . . . . . 3
General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Routine Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . 3
Filters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
SUPPLY FAN (BLOWER) SECTION . . . . . . . . . . . . . . 4
Supply Fan (Direct-Drive) . . . . . . . . . . . . . . . . . . . . . . 4
Staged Air Volume . . . . . . . . . . . . . . . . . . . . . . . . . . 13
COOLING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Condenser Coil . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Condenser Coil Maintenance and Cleaning
Recommendation . . . . . . . . . . . . . . . . . . . . . . . . . 13
Evaporator Coil . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Evaporator Coil Metering Devices . . . . . . . . . . . . . . 15
THERMOSTATIC EXPANSION VALVE (TXV) . . . . . 15
TXV Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Replacing TXV . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Refrigerant System Pressure Access Ports . . . . . . 16
PURON
®
(R-410A) REFRIGERANT . . . . . . . . . . . . . . 17
Refrigerant Charge . . . . . . . . . . . . . . . . . . . . . . . . . . 17
COMPRESSOR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Lubrication . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Replacing Compressor . . . . . . . . . . . . . . . . . . . . . . . 26
Compressor Rotation . . . . . . . . . . . . . . . . . . . . . . . . 26
Filter Drier . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Condenser-Fan Adjustment . . . . . . . . . . . . . . . . . . . 26
Troubleshooting Cooling System . . . . . . . . . . . . . . 27
CONVENIENCE OUTLETS . . . . . . . . . . . . . . . . . . . . 28
Convenience Outlets . . . . . . . . . . . . . . . . . . . . . . . . 28
Installing Weatherproof Cover . . . . . . . . . . . . . . . . . 28
Non-Powered Type . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Unit-Powered Type . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Duty Cycle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
Fuse on Powered Type . . . . . . . . . . . . . . . . . . . . . . . 29
SMOKE DETECTORS . . . . . . . . . . . . . . . . . . . . . . . . 29
System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
Controller . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
Smoke Detector Sensor . . . . . . . . . . . . . . . . . . . . . . 29
Smoke Detector Locations . . . . . . . . . . . . . . . . . . . . 30
FIOP Smoke Detector Wiring and Response . . . . . 31
SENSOR AND CONTROLLER TESTS . . . . . . . . . . . 32
Sensor Alarm Test . . . . . . . . . . . . . . . . . . . . . . . . . . 32
Controller Alarm Test . . . . . . . . . . . . . . . . . . . . . . . . 32
Dirty Controller Test . . . . . . . . . . . . . . . . . . . . . . . . . 32
Dirty Sensor Test . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
Changing the Dirt Sensor Test . . . . . . . . . . . . . . . . .33
Remote Station Test . . . . . . . . . . . . . . . . . . . . . . . . .33
SD-TRK4 Remote Alarm Test Procedure . . . . . . . .33
Remote Test/Reset Station Dirty Sensor Test . . . .33
Dirty Sensor Test Using an SD-TRK4 . . . . . . . . . . .34
Detector Cleaning . . . . . . . . . . . . . . . . . . . . . . . . . . .34
Indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .34
Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . .35
PROTECTIVE DEVICES . . . . . . . . . . . . . . . . . . . . . . .35
Compressor Protection . . . . . . . . . . . . . . . . . . . . . . .35
Relief Device . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .36
Control Circuit, 24-V . . . . . . . . . . . . . . . . . . . . . . . . .36
ELECTRIC HEATERS . . . . . . . . . . . . . . . . . . . . . . . . .37
Heater Installation (All Units) . . . . . . . . . . . . . . . . . .37
460V HIGH SCCR UNIT INSTALLATION
(65KA SCCR) . . . . . . . . . . . . . . . . . . . . . . . . . . . . .37
230V HIGH SCCR UNIT INSTALLATION
(60KA SCCR) . . . . . . . . . . . . . . . . . . . . . . . . . . . . .37
Completing Heater Installation . . . . . . . . . . . . . . . . .42
SYSTEMVU CONTROL SYSTEM . . . . . . . . . . . . . . . .43
SystemVu Interface . . . . . . . . . . . . . . . . . . . . . . . . . .43
Additional SystemVu Installation and
Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . .43
ECONOMIZER SYSTEMS . . . . . . . . . . . . . . . . . . . . .44
EconoMi$er2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .45
EconoMi$er IV (Field-Installed Accessory) . . . . . . .46
EconoMi$er X (Factory-Installed Option) . . . . . . . .52
PRE-START-UP/START-UP . . . . . . . . . . . . . . . . . . . .63
START-UP, GENERAL . . . . . . . . . . . . . . . . . . . . . . . .64
Unit Preparation . . . . . . . . . . . . . . . . . . . . . . . . . . . . .64
Additional Installation/Inspection . . . . . . . . . . . . . .64
Return-Air Filters . . . . . . . . . . . . . . . . . . . . . . . . . . . .64
Outdoor-Air Inlet Screens . . . . . . . . . . . . . . . . . . . . .64
Compressor Mounting . . . . . . . . . . . . . . . . . . . . . . .64
Internal Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .64
Refrigerant Service Ports . . . . . . . . . . . . . . . . . . . . .64
Compressor Rotation . . . . . . . . . . . . . . . . . . . . . . . .64
Cooling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .64
Heating . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .65
Ventilation (Continuous Fan) . . . . . . . . . . . . . . . . . .65
FASTENER TORQUE VALUES . . . . . . . . . . . . . . . . .65
START-UP, SYSTEMVU CONTROLS . . . . . . . . . . . .65
APPENDIX A — MODEL NUMBER
NOMENCLATURE . . . . . . . . . . . . . . . . . . . . . . . . . .66
APPENDIX B — PHYSICAL DATA . . . . . . . . . . . . . . .68
APPENDIX C — FAN PERFORMANCE . . . . . . . . . . .69
APPENDIX D — WIRING DIAGRAMS . . . . . . . . . . . .82
APPENDIX E — LOW AMBIENT CONTROL SENSOR
LOCATION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .111
50FC-*20-30
Single Package Rooftop Electric Cooling Unit
with Puron
®
(R-410A) Refrigerant
17.5-27.5 Nominal Tons

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Carrier 50FC M20 Series and is the answer not in the manual?

Carrier 50FC M20 Series Specifications

General IconGeneral
BrandCarrier
Model50FC M20 Series
CategoryAir Handlers
LanguageEnglish

Related product manuals