CONTENTS
Page
SAFETY
CONSIDERATIONS.1
GENERAL
.1
INSTALLATION
.2-13
Step
1
Select
Location
.2
Step
2
Provide
Air
For
Combustion
and
Ventilation.3
Step
3
Assemble
Furnace
.3
DRAFT
HOOD
Step
4
Size
Ductwork
.4
Step
5
Vent
Furnace
.4
MASONRY
CHIMNEY
TYPE
B-l
VENT
ATTIC
INSTALLATION
Step
6
Connect
Gas
Piping
.5
BURNER
ORIFICES
Step
7
Make
Electrical
Connections
.6
Step
8
Install
Filters.
11
Step
9
Reverse
Components
(if
required)
.
1
1
-
1
3
START-UP
AND
ADJUSTMENT
.13-15
SERVICE
AND
MAINTENANCE
.15-17
SAFETY
CONSIDERATIONS
These
instructions
are
intended
for
use
by
qualified
personnel
who
have
been
trained
in
installing
this
type
of
furnace.
Installation
of
this
furnace
by
an
unqualified
person
may
lead
to
equipment
damage
and/or
a
hazardous
condition
which
may
lead
to
personal
injury
GENERAL
This
furnace
is
designed
for
use
with
either
natural
or
liquefied
petroleum
(propane)
gases
and
has
been
design
certified
by
the
American
Gas
Association
It
is
shipped
as
a
packaged
unit,
complete
with
burners
and
controls,
and
requires
only
a
line
voltage
(115-v)
connection
to
the
Fig.
1
Furnace
Dimensions
(Model
58ED
Shown)
junction
box
and
a
thermostat
hookup
as
shown
in
the
wiring
diagram.
The
design
of
the
furnace
is
such
that
the
burners,
controls
and
flue
outlet
can
be
assembled
on
the
same
side
to
facilitate
servicing
for
installations
where
only
limited
access
to
the
unit
is
available.
(See
Step
9
Reverse
Components.)
The
58ED
furnace
(with
intermittent
electronic
ignition)
is
shown
in
Fig.
1.
This
furnace
has
been
designed
to
interface
with
split-
system
cooling
equipment
(approved
by
UL)
to
provide
year-round
air
conditioning.
The
blower
is
sized
for
both
heating
and
cooling.
Table
1
provides
physical
data
and
dimensions
of
the
furnaces,
and
Table
2
pro¬
vides
airflow
data.
The
furnace
installation
must
conform
with
local
building
codes
or,
in
the
absence
of
local
codes,
with
the
National
Fuel
Gas
Code,
NFPA54-1984/ANSI
Z223.1-
1984
For
complete
information
on
installation
standards
consult
the
National
Fuel
Gas
Code,
obtainable
at
a
nominal
cost
from
the
National
Fire
Protection
Associa¬
tion,
Inc.,
Batterymarch
Park,
Quincy
MA
02269
or
the
Table
1
Physical
Data
and
Dimensions
SIZE
58ED/PB
FURNACE
050
075
100
125
140
INPUT
(1000
Btuh)*
50
75
100
125
140
HEATING
CAPACITY
(1000
Btuh)f
Non-Weatherized
38
56
75
94
105
Indoor
39
58
77
96
108
TEMPERATURE
RISE
(F)
35-65
40-70
40-70
40-70
DIMENSIONS
(ft-in.)
Length
A
4-6
4-6
4-6
4-8
4-8
Width
B
1-
Vk
1-
Vk
1-5
1-
87
2
Duct
Opening
C
0-11%
0-11%
1
-37a
1-
6%
1-107a
Vent
Diameter
D
0-4
0-4
0-5
0-6
E
1-
8%
1-
8
3
/4
1-874
1-
874
1-
7%
F
0-
87s
0-
87a
0-8%
0-
97a
0-
97a
G
1-4
1-4
1-4
1-
574
1-
574
i„i
Q
*
it
58ED
1-
974
1-
974
1-974
1-1174
1-1174
Gas
Inlet
11
50P0
1-
7%
1-
7
3
/4
1-7
3
/4
1-
574
1-
574
NUMBER
OF
BURNERS
2
3
4
5
6
SHIPPING
WEIGHT
(lb)
155
165
190
230
250
*Ratings
shown
are
for
elevations
up
to
2000
ft
above
sea
level.
-(-Determined
as
per
U
S
Government
standard
tests
For
elevations
above
2000
ft,
deduct
4%
of
input
capacity
for
each
1000
ft
above
sea
level
Manufacturer
reserves
the
right
to
discontinue,
or
change
at
any
time,
specifications
or
designs
without
notice
and
without
incurring
obligations.
Bookll
14
PC
101
Catalog
No
535-834
Printed
in
U
S
A
Form
58ED,PB-1SI
Pg
1
6-85
Replaces:
58PB-1
SI
Tab
|
6a
18a
For
replacement
items
use
Carrier
Specified
Parts.