AFS AccuControl Liquid Toolbar AFS Pro 700
Quick Reference Card (v28.* and after)
REQUIREMENTS
The following actions are required for proper operation. Working
thru this document in order will properly set up your Liquid
Application system. This guide is to be used as quick reference
only. Insert a data card in the display before turning the display on.
1 – GENERAL NAVIGATION
1.1 Main Screens
2 – SET-UP SCREENS
2.1 Operator
Toolbox>Oper
a) Create an operator.
b) Select preferred units
of measurement.
2.2 GPS Setup
Toolbox>GPS
a) Verify GPS Location
b) Verify Offsets
c) Verify DGPS Type
Main screen
Status/Warnings
Navigation Bar
Left Hand Area
3 – LIQUID TOOLBAR CONFIGURATION 3 – LIQUID TOOLBAR CONFIGURATION – continued
Toolbox>AccuCtrl
Note: Activation is required (Toolbox>Activate)
prior to these steps.
3.1 Basic Setup
a) Select AccuCtrl
Operation [Liquid]
b) Select AccuCtrl
Installed [Yes]
c) Create New Implement
d) Select Implement Type
[Liquid Toolbar]
3.2 Implement Configuration
a) Press ‘Setup’
b) Select Planter Type
c) Select Vehicle Type
d) Set Number of Drive
Sections [A]
NOTE! Section Shut-Off
Valve Control information
entered in 3.3
e) Set Number of Rows [B]
f) Enter Row width [C]
g) Enter Bar Distance
in Inches (axle to
application point) [D]
NOTE! Verify GPS Offset (Toolbox>GPS)
h) Measure Implement Right/Left Offset [E]
i) Enter Rows Per Drive Section
j) Press ‘Done’
NOTE: The next setup steps may or may not be needed.
The configuration of the Liquid Toolbar determines the
need for set-up. If the implement is not equipped with
this capability, leave the setup as ‘No’.
3.3 Section Control Setup
(If equipped with Section Shutoff Valves)
a) Select Section
Control [Yes]
b) Press ‘Setup’
c) Select number of
Control Modules
d) Assign Module Serial
Numbers (starting w/
modules on LH side)
e) Assign Module Rows
Per Section (Number of
Rows per shutoff valve)
f) Select Control Polarity
Note: Active On is common for Section Control Valves.
Active Off is common for LiquiBlock Valves
g) Select ‘Done’
3.4 Liquid Drive Set-up (If equipped w/ hydraulic drive)
a) Select Liquid
Drive [Yes]
b) Press ‘Setup’
c) Verify Number of
Control Modules
d) Select Drive Type
(Servo or PWM)
e) Assign Module Serial
Numbers (starting w/
modules on LH side)
f) Assign Plumbing Type
(Servo only)
g) Enter Drive Pulses/Gal
for each Drive
Note: Pulses/gallon will be found on the liquid ow meter.
Some ow meters are measure in pulses/10 gallons. If this is
the case, divide that value by 10 to nd pulses/gallon.
h) Select Master Valve
i) Select Pump Disarm
j) Select Section Off Behavior (Lock At Last or Turn Off)
k) Press ‘Done’