CHALLENGER SECURITY PRODUCTS
UNIT 2 /4 ARKWRIGHT COURT
FYLDE IND ESTATE BLACKPOOL
LANCASHIRE FY4 5DR TEL 01253 792898 TECHNICAL
The Challenger "Spirit" is a high quality external combined sounder and
strobe unit. Features include a digital timed SAB with dual fail safe action, a
high efficiency Piezo sounder and an integral high intensity double lens
strobe.
Technical Description of the SPIRIT
+
This requires a constant 12V and 0V from the control panel
HOLD OFF
This "HOLDS OFF" the piezo siren in normal operation
.
-
It also allows the battery to be trickle charged
STB
-
Provides an output from the control panel to flash the strobe and is
independent
of the sounder inputs.
TRG
-
In normal operation this activates the sounder only when a Negative
Trigger is
applied by the control panel.
PIEZO
Provides the siren output to drive the piezo sounder
RTN
-
In normal operation this supplies a
permanent signal to the control panel as
part of the 24 hour tamper loop
MICRO
This is for N/C Tamper switches, which for
m part of the 24 hour tamper
SWITCH
circuit
BAT
Battery Link. After completing all connections this link must be move
d to
the ON position before fitting the bell box cover.
This enables charging of the battery and correct function of the SPIRIT.
SAB
Self activating bell ( use for primary sounder )
SCB
Self contained bell ( use for secondary sounder )
Note:
Isolate strobe before
removing
the cover ( HIGH VOLTAGE )