EasyManuals Logo
Home>Cisco>Security System>ISA 3000

Cisco ISA 3000 Product Documentation

Cisco ISA 3000
12 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #5 background imageLoading...
Page #5 background image
5
Product Documentation and Compliance Information for the Cisco ISA 3000 Industrial Security Appliance
78-100733-01B0
Grounding the ISA 3000
Make sure to follow any grounding requirements at your site. The device must be connected to a reliable
earth ground. Install the ground wire in accordance with local electrical safety standards.
Note The ground lug is not supplied with the device. You can use either a single ring terminal, two single ring
terminals, or a double ring terminal.
Warning
This equipment must be grounded. Never defeat the ground conductor or operate the equipment in the
absence of a suitably installed ground conductor. Contact the appropriate electrical inspection
authority or an electrician if you are uncertain that suitable grounding is available.
Statement 1024
Warning
This equipment is intended to be grounded to comply with emission and immunity requirements.
Ensure that the device functional ground lug is connected to earth ground during normal use.
Statement 1064
Warning
This equipment needs to be grounded. Use a green and yellow 14 to 16 AWG ground wire to connect
the host to earth ground during normal use.
Statement 242
Warning
This equipment must be grounded. Never defeat the ground conductor or operate the equipment in the
absence of a suitably installed ground conductor. Contact the appropriate electrical inspection
authority or an electrician if you are uncertain that suitable grounding is available.
Statement 1024
Warning
When installing or replacing the unit, the ground connection must always be made first and
disconnected last.
Statement 1046
To ground the ISA 3000 to earth ground, follow these steps:
Step 1
Use a standard Phillips screwdriver or a ratcheting torque screwdriver with a Phillips head to remove the ground
screw from the front panel of the device.
Step 2
Use a wire stripping tool to strip the 14-to-16 AWG grounding wire to 0.22 in. (5.56 mm).
Step 3
Insert the ground wire into the ring terminal lug, and using a crimping
tool, crimp the terminal to the wire.
Step 4
Slide the ground screw through the terminal.
332163

Other manuals for Cisco ISA 3000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco ISA 3000 and is the answer not in the manual?

Cisco ISA 3000 Specifications

General IconGeneral
BrandCisco
ModelISA 3000
CategorySecurity System
LanguageEnglish

Related product manuals