60-Watt PoE Ports—Highlighted in yellow. The 60-Watt PoE ports double the PoE power to 60W. This
is not found on the 250 devices nor on the SF350-48P device.
SFP+ Port (if present)—The small form-factor pluggable plus (SFP+) are connection points for modules
so that the switch can link to other switches. These ports are also commonly referred to as mini 10GigaBit
Interface Converter ports. The term SFP+ is used in this guide.
The SFP+ ports are compatible with the following Cisco SFP 1G optical modules MGBSX1,
MGBLH1, MGBT1, as well as other brands.
The Cisco SFP+ 10G optical modules that are supported in the Cisco switches are: SFP-10G-SR,
SFP-10G-LR, SFP-10G-SR-S, and SFP-10G-LR-S.
The Cisco SFP+ Copper Cable modules that are supported in the Cisco switches are:
SFP-H10GB-CU1M, SFP-H10GB-CU3M, and SFP-H10GB-CU5M.
The SFP+ port is a combination port, shared with one other RJ-45 port. When the SFP+ is active,
the adjacent RJ-45 port is disabled.
The LEDs of the corresponding RJ-45 port flash green to respond to the SFP interface traffic.
Some SFP interfaces are shared with one other RJ-45 port, called a combo port. When the SFP is active,
the adjacent RJ-45 port is disabled.
OOB Port (if present)—The Out of Band (OOB) port is a CPU Ethernet port that can be used only as a
management interface. Bridging between the OOB port and the in-band Layer 2 interface is not supported.
This does not appear on 250 devices.
Front Panel LEDs
The following are the global LEDs found on the devices:
System—(Green) The LED lights steady when the switch is powered on, and flashes when booting,
performing self-tests, or acquiring an IP address. If the LED flashes Amber, the switch has detected a
hardware failure, a firmware failure, and/or a configuration file error.
System LED - Every 20 seconds, the System LED will flash according to unit ID of the member unit.
Flash = LED going off and then on again.
According to unit ID of the unit. This means
Unit 1 (if not active unit) - system LED will flash 1 time
Unit 2 (if not active unit) - system LED will flash 2 times
Unit 3 - system LED will flash 3 times
Unit 4 -system LED will flash 4 times;
The duration of each flash (LED off time) will be as follows:
LED off time (in each flash) ~ 0.5 seconds.
“Interim” LED on (between 2 LED offs) ~ 0.5 seconds
Get To Know Your Switch
7
Get To Know Your Switch
Front Panel LEDs

Other manuals for Cisco SF350-24P

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco SF350-24P and is the answer not in the manual?

Cisco SF350-24P Specifications

General IconGeneral
BrandCisco
ModelSF350-24P
CategorySwitch
LanguageEnglish

Related product manuals