EasyManuals Logo
Home>Cisco>Server>UCS C240 M3

Cisco UCS C240 M3 User Manual

Cisco UCS C240 M3
64 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #18 background imageLoading...
Page #18 background image
Cisco UCS C240 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)
18
CONFIGURING the SERVER
Table 6 Available Mezzanine Card RAID Options
Product ID (PID) PID Description
RAID Controllers
UCSC-RAID-11-C240 Cisco UCSC RAID SAS 2008M-8i Mezzanine Card (RAID 0, 1, 10, 5, and 50
supported), operating at 6 Gbs.
Supports up to 8 or 16 internal SAS or SATA drives (depending on the
backplane size). SAS and SATA drives can be mixed.
Factory-configured RAID options available: RAID 0, 1, 10, and 5 (see the
RAID PIDs section in this table)
No data cache backup
UCSC-RAID-MZ-240 Cisco UCSC RAID SAS 2008M-8i Mezzanine Card (RAID 0, 1, 10 supported),
operating at 6 Gbs.
Supports up to 8 or 16 internal SAS or SATA drives (depending on the
backplane size). SAS and SATA drives can be mixed.
Factory-configured RAID options available: RAID 0, 1, and 10 (see the RAID
PIDs section in this table)
No data cache backup
Table 7 Available Plug-In PCIe Card RAID Options
Product ID (PID) PID Description
RAID Controllers
UCS-RAID-9266NB LSI MegaRAID SAS 9266-8i RAID controller card with no data cache backup
(RAID 0, 1, 10, 5, 6, 50, and 60 supported), operating at 6 Gbs.
Installed by default in the half-height PCIe slot (slot 2)
Supports up to 24 internal SAS and/or SATA drives. SAS and SATA drives can
be mixed.
Includes 1 GB of write cache
Factory-configured RAID options available: RAID 0, 1, 10, 5, and 6 (see the
RAID PIDs section in this table)
UCS-RAID-9266CV LSI MegaRAID 9266CV-8i RAID controller card with data cache backup (RAID 0,
1, 10, 5, 6, 50, 60), operating at 6 Gbs.
Supports up to 24 internal SAS or SATA drives. SAS and SATA drives can be
mixed.
Includes a 1 GB Transportable Memory Module (TMM) and SuperCap power
module for data cache backup
Factory-configured RAID options available: RAID 0, 1, 10, 5, and 6 (see the
RAID PIDs section in this table)
Battery Backup Option
UCS-RAID-CV-SC= LSI CacheVault Power Module for 9266CV-8i

Other manuals for Cisco UCS C240 M3

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco UCS C240 M3 and is the answer not in the manual?

Cisco UCS C240 M3 Specifications

General IconGeneral
Processor cores8
Processor modelE5-2600
Processor frequency2.7 GHz
Number of processors installed2
HDD size2.5 \
RAID supportYes
HDD interface-
Optical drive typeNo
Total storage capacity300 GB
Maximum storage capacity- TB
Number of HDDs installed16
Memory slots24
Internal memory96 GB
Memory clock speed1866 MHz
Internal memory typeDDR3-SDRAM
Maximum internal memory- GB
USB 2.0 ports quantityUSB 2.0 ports have a data transmission speed of 480 Mbps, and are backwards compatible with USB 1.1 ports. You can connect all kinds of peripheral devices to them.
PCI Express x8 slots3
Chassis typeRack (2U)
Power supply650 W
Operating altitude0 - 3000 m
Non-operating altitude0 - 12000 m
Operating temperature (T-T)-40 - 70 °C
Storage relative humidity (H-H)5 - 93 %
Operating relative humidity (H-H)10 - 90 %
Harmonized System (HS) code84714100
Weight and Dimensions IconWeight and Dimensions
Depth712 mm
Width445 mm
Height87 mm