Cisco UCS C240 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)
60
TECHNICAL SPECIFICATIONS
For configuration-specific power specifications, use the Cisco UCS Power Calculator at this URL:
https://express.salire.com/Go/Cisco/Cisco-UCS-Power-Calculator.aspx.
Maximum AC input current 7.6 A peak at 100 VAC
3.65 A peak at 208 VAC
Maximum output power for each
power supply
650 W
Power supply output voltage Main power: 12 VDC
Standby power: 12 VDC
Power supply efficiency CSCI Platinum
NOTE: AC input connector is an IEC 320 C-14 15A/250VAC power inlet.
Table 33 UCS C240 M3 SFF Power Specifications (1200 W power supply)
Description Specification
AC input voltage range 90 to 264 VAC (self-ranging, 180 to 264 VAC nominal)
AC input frequency Range: 47 to 63 Hz (single phase, 50 to 60Hz nominal)
Maximum AC inrush current 30 A
Maximum AC input current 11 A peak at 100 VAC
7 A peak at 208 VAC
Maximum output power for each
power supply
1200 W at 200 to 240 V
800 W at 100 to 120 V
Power supply output voltage Main power: 12 VDC
Standby power: 12 VDC
Power supply efficiency CSCI Platinum
NOTE: AC input connector is an IEC 320 C-14 15A/250VAC power inlet.
Table 32 UCS C240 M3 SFF Power Specifications (650 W power supply) (continued)
Description Specification