EasyManuals Logo
Home>Curtis>Coffee Maker>D60GT

Curtis D60GT User Manual

Curtis D60GT
6 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Conventions
WARNINGS – To help avoid personal injury
Important Notes/Cautions – from the factory
Sanitation Requirements
1
Models Included
D60GT
CAUTION: DO NOT
connect this brewer to hot
water. The inlet valve is
not rated for hot water.
CAUTION: Please use
this setup procedure
before attempting to use
this brewer. Failure to follow the
instructions can result in injury or the
voiding of the warranty.
ISO 9001 REGISTERED
C
WARNING HOT LIQUID,
Scalding may occur.
Avoid splashing.
Important Safeguards/Conventions
Service Manual, D60GT
This appliance is designed for commercial use. Any servicing other than cleaning and maintenance should be performed by an autho-
rized Wilbur Curtis service center.
•Do NOT immerse the unit in water or any other liquid
•To reduce the risk of re or electric shock, do NOT open top or rear panel. No user serviceable parts inside. Repair should
be done only by authorized service personnel.
•Keep hands and other items away from hot parts of unit during operation.
•Never clean with scouring powders, bleach or harsh implements.
Your Curtis G3 System is Factory Pre-Set and Ready to Go… Right from the Carton.
Following are the Factory Settings for your D60GT
Coffee Brewing Systems:
Brew Temperature = 200°F
Brew Volume = Set to dispensing vessel requirements (60 oz)
Generally there will never be a reason to change your G3 programming. However, should you need to make slight adjustments to meet
your brewing needs, programming instructions are provided later in this manual.
System Requirements:
Water Source20–90PSI.Musthaveaminimumowrateof½GPM(preferredowrateis1gpm).
Electrical: See attached schematic for standard model or visit www.wilburcurtis.com for your model.
Equipment to be installed to comply with applicable federal, state, or local plumbing/electrical codes having jurisdiction.
SETUP STEPS
Theunitshouldbelevel(lefttorightandfronttoback),locatedonasolidcountertop.Connectawaterlinefromthewaterltertothe
brewer.NOTE:Sometypeofwaterltrationdevicemustbeusedtomaintainatrouble-freeoperation.(Inareaswithextremelyhard
water,wesuggestthatasedimentaryandtaste&odorlterbeinstalled.)Thiswillprolongthelifeofyourbrewingsystemandenhance
coffee quality.
1.A3/8”NPTx1/4”Flareelbowhasbeensuppliedforwaterlineconnection.Useadequatewatertubing,sizedtoprovideaminimum
of ½ GPM.
2. Connect the unit to an appropriate electrical power circuit.
3.Turnonthetoggle(STANDBY/ON)switchbehindtheunit.Theheatingtankwillstarttoll.Whenthewaterlevelinthetankrisesto
thecorrectvolume,theheatingelementwillenergizeautomatically.G3systemseliminateelementburn-outduetoanunder-lled
heating tank.
4.Theheatingtankwillrequire20to30minutestoreachoperatingtemperature(200°F),indicatedbytheREADY-TO-BREWlight.
5.Priortobrewing,dispense12ouncesofhotwaterthroughthehotwaterfaucet.
6. Brewacycleofatleast12ounces,topurgethewaterlinesofanyairthatmaybetrappedafterlling.
BREWING INSTRUCTIONS
1.BrewershouldbeON(Conrmatreartoggleswitch,thenpressON/OFFbutton).Ready-to-Brewshouldbedisplayed.
2. Place a clean, empty decanter on brew deck.
3.Placeanewlterinbrewcone.
4.Pourground
coffee into
brewcone.
6. Press
Brew
button.
Wi l b u r Cu r t i s Co m p a n y , in C .
5. Position
brewcone
into brew
rails.
WILBUR CURTIS COMPANY
Montebello, CA 90640
CAUTION: When
cleaning, DO NOT use
powders, liquids, cleans-
ers, or any substance containing
chlorine. These products promote
corrosion, cause pitting of
stainless steel and will void the
warranty.
NSF International requires the following water connection:
1. A quick disconnect or additional coiled tubing (at least 2x the depth of the unit) so that the machine can be moved for
cleaning underneath.
2. This equipment is to be installed with adequate backow protection to comply with applicable federal, state and local
codes..
3. Water pipe connections and xtures directly connected to a potable water supply shall be sized, installed and main-
tained in accordance with federal, state, and local codes.

Other manuals for Curtis D60GT

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Curtis D60GT and is the answer not in the manual?

Curtis D60GT Specifications

General IconGeneral
BrandCurtis
ModelD60GT
CategoryCoffee Maker
LanguageEnglish

Related product manuals