CET2000B-RF
4
1. The clamp on sensor should
be mounted onto the
cylinder wall at a height
equivalent to ½ the height
of the cylinder. Care should
be taken to remove any
insulation material from
the cylinder and to ensure
that the copper surface of
the cylinder is clean. See
diagram opposite for details.
This product should only be installed by a qualied
electrician or competent heating installer, and must be
in accordance with local wiring regulations.
1/2 c
ylinder
height
For insulation thicker than 25mm
and up to 55mm thick, use the
extra cover supplied as a spacer to
ensure that the sensor is held in
firm contact with the cylinder wall.
!