EasyManuals Logo
Home>Danfoss>Thermostat>SET 3E

Danfoss SET 3E Installation Guide

Danfoss SET 3E
16 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #14 background imageLoading...
Page #14 background image
SET3E
14
GB
DANFOSS RANDALL
SET3E
(PUMPED)
MAINS WATER HEATING
NOTE
This conversion
applies only if..
An additional
terminal block is
required where these
disconnected leads
(or pairs of leads)
should be terminated
N L ON COM OFF ON COM OFF
NL123456 ABCD
DANFOSS RANDALL 922/972 N L 3 2 1 6 5 4
Pumped/Gravity link
is set to pumped
DANFOSS RANDALL 4033 7 6 4 1 5 2 - 3
DANFOSS RANDALL SET5 N L 1 2 3 4 5 6
Pumped/Gravity link
is set to pumped
GLOWWORM MASTERMIND N L 3 - 1 4 - 2
Pumped/Gravity link
is set to pumped
HONEYWELL ST7100 N L 8 6 7 5 3 4
HONEYWELL ST6300 N L 3 - 1 4 - 2
HONEYWELL ST6400 N L 3 - 1 4 - 2
HORSTMANN 423 AMETHYST 7 & 10 2, 3 1 5 - 4 7 - 6 8
HORSTMANN 424 GEM 2, 3 1, 10 4 5 6 7 8 9
Terminal 5, 8 & 10
are linked
HORSTMANN LEUCITE 423 & 424 2 1 3 5 4 6 7 8
Terminals 5 & 7 are
linked
HONEYWELL ST669 N L 6 8 7 3 5 4
LANDIS & GYR RWB2 N L 3 - 1 4 - 2
Pumped/Gravity link
is set to pumped