VLT
®
5000 Series
Programming
Description of choice:
Set the desired time.
318 Function after time out
(LIVE ZERO FUNCT.)
Value:
Off (OFF)
[0]
Freeze output frequency (FREEZE OUTPUT FREQ.)
[1]
Stop (STOP)
[2]
Jog (JOGGING)
[3]
Max. speed (MAX SPEED)
[4]
Stop and trip (STOP AND TRIP)
[5]
Function:
This parameter allows a choice of the function to
be activated if the input signal on terminal 60 drops
below 2 mA, provided parameter 315 has been set
higher than 2 mA and that the preset time for time-out
(parameter 317) has been exceeded.
If more time-outs occur at the same time the
frequency converter will give the following priority
to the time-out function:
1. Parameter 318 Function after time out
2. Parameter 346 Function after encoder loss
3. Parameter 514 Bus time interval function
Description of choice:
The output frequency of the frequency converter can be:
- frozen at the present value
- overruled to stop
- overruled to jog frequency
- overruled to max. frequency
- overruled to stop with subsequent trip.
= factory setting. () = display text [] = value for use in communication via serial communication port
MG.51.A9.02 - VLT is a registered Danfoss trademark
129

Table of Contents

Other manuals for Danfoss VLT 5000 Crane Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss VLT 5000 Crane Series and is the answer not in the manual?

Danfoss VLT 5000 Crane Series Specifications

General IconGeneral
BrandDanfoss
ModelVLT 5000 Crane Series
CategoryMedia Converter
LanguageEnglish

Related product manuals