EasyManuals Logo
Home>Danfoss>Media Converter>VLT 5000 Crane Series

Danfoss VLT 5000 Crane Series Operating Instructions

Danfoss VLT 5000 Crane Series
192 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #15 background imageLoading...
Page #15 background image
VLT
®
5000 Series
Cable lengths, cross-sections and connectors:
Max. motor cable length, screened cable ..................................................................................................... 150 m
Max. motor cable length, unscreened cable ................................................................................................. 300 m
Max. motor cable length, screened cable VLT 5011 380-500 V .................................................................... 100 m
Max. motor cable length, screened cable VLT 5011 525-600 V
and VLT 5008, normal overload mode, 525-600 V ..........................................................................................50m
Max. brake cable length, screened cable ........................................................................................................ 20 m
Max. loadsharing cable length, screened cable ..................................... 25 m from frequency converter to DC bar.
Max. cable cross-section for motor, brake and loadsharing, see Electrical data
Max. cable cross-section for 24 V external DC supply
- VLT 5001-5027 200-240 V; VLT 5001-5102 380-500 V; VLT 5001-5062 525-600 V ................. 4 mm
2
/10 AWG
- VLT 5032-5052 200-240 V; VLT 5122-5552 380-500 V; VLT 5042-5602 525-690 V .............. 2.5 mm
2
/12 AWG
Max. cross-section for control cables ....................................................................................... 1.5 mm
2
/16 AWG
Max. cross-section for serial communication ............................................................................ 1.5 mm
2
/16 AWG
If UL/cUL is to be complied with, copper cable withtemperatureclass60/75°Cmustbeused
(VLT 5001 - 5062 380 - 500 V, 525 - 600 V and VLT 5001 - 5027 200 - 240 V).
If UL/cUL is to be complied with, copper cable with temperature class 75°C must be used
(VLT 5072 - 5552 380 - 500 V, VLT 5032 - 5052 200 - 240 V, VLT 5042 - 5602 525 - 690 V).
Connectors are for use of both copper and aluminium cables, unless other is specified.
Accuracy of display readout (parameters 009-012):
Motor current [6] 0-140% load ............................................................... Max. error: ±2.0% of rated output current
Torque % [7], -100 - 140% load ...................................................................... Max. error: ±5% of rated motor size
Output [8], power HP [9], 0-90% load ................................................................... Max. error: ±5% of rated output
Control characteristics:
Frequency range .................................................................................................................................. 0 - 1000 Hz
Resolution on output frequency ............................................................................................................. ±0.003 Hz
System response time ............................................................................................................................... 3 msec.
Speed, control range (open loop) ..................................................................................... 1:100 of synchro. speed
Speed, control range (closed loop) ................................................................................. 1:1000 of synchro. speed
Speed, accuracy (open loop) ............................................................................ < 1500 rpm: max. error ± 7.5 rpm
..................................................................................................... >1500 rpm: max. error of 0.5% of actual speed
Speed, accuracy (closed loop) .......................................................................... < 1500 rpm: max. error ± 1.5 rpm
..................................................................................................... >1500 rpm: max. error of 0.1% of actual speed
Torque control accuracy (open loop) ................................................ 0- 150 rpm: max. error ±20% of rated torque
................................................................................................... 150-1500 rpm: max. error ±10% of rated torque
........................................................................................................ >1500 rpm: max. error ±20% of rated torque
Torque control accuracy (speed feedback) ............................................................. Max. error ±5% of rated torque
All control characteristics are based on a 4-pole asynchronous motor
Externals:
Enclosure (dependent on power size) ................................................................ IP 00, IP 20, IP 21, Nema 1, IP 54
Vibration test .................................. 0.7 g RMS 18-1000 Hz random. 3 directions for 2 hours (IEC 68-2-34/35/36)
Max. relative humidity ................................................................................ 93 % (IEC 68-2-3) for storage/transport
Max. relative humidity ............................................... 95 % non condensing (IEC 721-3-3; class 3K3) for operation
Aggressive environment (IEC 721 - 3 - 3) ................................................................................ Uncoated class 3C2
Aggressive environment (IEC 721 - 3 - 3) .................................................................................... Coated class3C3
Ambient temperature IP 20/Nema 1 (high overload torque 160%) .......... Max. 45°C (24-hour average max. 40°C)
Ambient temperature IP 20/Nema 1 (normal overload torque 110%) ....... Max. 40°C (24-hour average max. 35°C)
Ambient temperature IP 54 (high overload torque 160%) ....................... Max. 40°C (24-hour average max. 35°C)
Ambient temperature IP 54 (normal overload torque 110%) .................... Max. 40°C (24-hour average max. 35°C)
Ambient temperature IP 20/54 VLT 5011 500 V ..................................... Max. 40°C (24-hour average max. 35°C)
MG.51.A9.02 - VLT is a registered Danfoss trademark
14

Table of Contents

Other manuals for Danfoss VLT 5000 Crane Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss VLT 5000 Crane Series and is the answer not in the manual?

Danfoss VLT 5000 Crane Series Specifications

General IconGeneral
BrandDanfoss
ModelVLT 5000 Crane Series
CategoryMedia Converter
LanguageEnglish

Related product manuals