Page #145 background image
Digital input
505-508
Bus Control com-
mand
0 0 0
0 1 0
1 0 0
111
Logic or [3] is selected if the control command in ques-
tion is to be activated when a signal is given (active
signal = 1) either via a control word or via a digital input.
Digital input
505-508
Bus Control com-
mand
0 0 0
0 1 1
1 0 1
111
NOTE
Parameters 502-504 deal with stop func-
tions - see examples regarding 502
(coasting) below. Active stop command
"0".
Parameter 502 = Logic and
Digital input
Bus Control command
0 0 1 Coasting
0 1 0 Motor running
1 0 0 Motor running
110 Motor running
Parameter 502 = Logic or
Digital input
Bus Control command
0 0 1 Coasting
0 1 1 Motor running
1 0 1 Motor running
110 Motor running
506 Reversing
(REVERSING SELECT)
Value:
Digital input (DIGITAL INPUT) [0]
Bus (SERIAL PORT) [1]
Logic and (LOGIC AND) [2]
Logic or (LOGIC OR) [3]
Function:
See description under parameter 502.
Description of choice:
See description under parameter 502.
509 Bus jog 1
(BUS JOG 1 FREQ.)
Value:
0.0 - parameter 202
10.0 Hz
Function:
This is where to set a fixed speed (jog) that is activated
via the serial communication port.
This function is the same as in parameter 213.
Description of choice:
The jog frequency f
JOG
can be selected in the range
between f
MIN
(parameter 201) and f
MAX
(parameter
202).
510 Bus jog 2
(BUS JOG 2 FREQ.)
Value:
0.0 - parameter 202
10.0 Hz
Function:
This is where to set a fixed speed (jog) that is activated
via the serial communication port.
This function is the same as in parameter 213.
Description of choice:
The jog frequency f
JOG
can be selected in the range
between f
MIN
(parameter 201) and f
MAX
(parameter
202).
512 Telegram profile
(TELEGRAM PROFILE)
Value:
Fieldbus profile (FIELDBUS PROFILE) [0]
FC Drive (FC DRIVE) [1]
Function:
There is a choice of two different control word profiles.
Description of choice:
Select the desired control word profile.
VLT
®
5000 Series
= factory setting, () = display text, [] = value for use in communication via serial communication port
142 MG.51.C5.22 - VLT
p
is a registered Danfoss trademark.

Table of Contents

Other manuals for Danfoss VLT 5000 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss VLT 5000 Series and is the answer not in the manual?

Danfoss VLT 5000 Series Specifications

General IconGeneral
BrandDanfoss
ModelVLT 5000 Series
CategoryDC Drives
LanguageEnglish

Related product manuals