Compact, AC line supply 3 x 200-240 V
According to international requirements VLT type 5008 5011 5016 5022 5027
Normal overload torque (110 %):
Output current
I
VLT,N
[A]
32 46 61.2 73 88
I
VLT, MAX
(60 s)
[A]
35.2 50.6 67.3 80.3 96.8
Output (240 V) S
VLT,N
[kVA]
13.3 19.1 25.4 30.3 36.6
Typical shaft output
P
VLT,N
[kW]
7.5 11 15 18.5 22
Typical shaft output
P
VLT,N
[HP]
10 15 20 25 30
High overload torque (160 %):
Output current
I
VLT,N
[A]
25 32 46 61.2 73
I
VLT, MAX
(60 s)
[A]
40 51.2 73.6 97.9 116.8
Output (240 V) S
VLT,N
[kVA]
10 13 19 25 30
Typical shaft output
P
VLT,N
[kW]
5.5 7.5 11 15 18.5
Typical shaft output
P
VLT,N
[HP]
7.5 10 15 20 25
Max. cable cross-section to motor, IP 54 16/6 16/6 35/2 35/2 50/0
brake and load sharing [mm
2
/AWG]
2) 5)
IP 20 16/6 35/2 35/2 35/2 50/0
Min. cable cross-section to motor, brake and
load sharing
4)
[mm
2
/AWG]
2)
10/8 10/8 10/8 10/8 16/6
Rated input current
(200 V) I
L,N
[A]
32 46 61 73 88
Max. cable cross-section, IP 54 16/6 16/6 35/2 35/2 50/0
power [mm
2
]/[AWG]
2) 5)
IP 20 16/6 35/2 35/2 35/2 50/0
Max. pre-fuses
[-]/UL
1)
[A]
50 60 80 125 125
Efficiency
3)
0.95 0.95 0.95 0.95 0.95
Weight IP 20 EB [kg] 21 25 27 34 36
Weight IP 54 [kg] 38 40 53 55 56
Power loss at max. load.
- high overload torque
(160 %)
[W]
340 426 626 833 994
- normal overload torque
(110 %)
[W]
426 545 783 1042 1243
Enclosure
IP 20/
IP 54
IP 20/
IP 54
IP 20/
IP 54
IP 20/
IP 54
IP 20/
IP 54
1. For type of fuse, see section Fuses.
2. American Wire Gauge.
3. Measured using 100 ft [30 m] shielded motor cables at rated load and rated frequency.
4. Min. cable cross-section is the smallest cable cross-section allowed to be fitted on the terminals to comply with IP 20. Always comply
with national and local regulations on min. cable cross-section.
5. Aluminum cables with cross-section above 0.054 in
2
[35 mm
2
] must be connected by use of an AI-Cu connector.
VLT
®
5000 Series
14 MG.51.C5.22 - VLT
p
is a registered Danfoss trademark.

Table of Contents

Other manuals for Danfoss VLT 5102

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss VLT 5102 and is the answer not in the manual?

Danfoss VLT 5102 Specifications

General IconGeneral
BrandDanfoss
ModelVLT 5102
CategoryMedia Converter
LanguageEnglish

Related product manuals