1. Description of the modifications
A thermal fuse has been added in the upper part of the heat exchanger front plate. The thermal fuse is connected in
series with the overheating safety thermostat of the heat exchanger.
The thermal fuse shuts down the boiler if the temperature reaches 128 °C and the error E13 appears.
Application date in series: 22 september 2014.
As of serial number 1426209919550.
During the annual maintenance, check the burner plate insulation and imperatively replace the gaskets. In spare parts,
the burner plate insulation is systematically delivered with a thermal fuse, which is to be mounted on the heat exchanger
front plate.
The thermal fuse is also delivered with the maintenance kit available from the Spare Part Centre (see kits hereafter).
Z
see the leaflet delivered with the kit : Reference 7619580 (Click on the reference to open the link).
New version Previous version
Thermal fuse
TB