Configuring Switching Information 413
VLAN Mode
— Enables or disables the MLD Snooping Querier on the VLAN selected in the VLAN
ID field.
Querier Election Participate Mode
— Enables or disables the MLD participation in election mode by
the Snooping Querier. When this mode is disabled, upon seeing another querier of same version in the
VLAN, the Snooping Querier transitions to non-querier state. When this mode is enabled, the
Snooping Querier participates in querier election, where in the lowest IP address wins the querier
election and operates as the querier in that VLAN. The other querier transitions to non-querier state.
Snooping Querier VLAN Address
— Specifies the Snooping Querier address to be used as source
address in periodic MLD queries sent on the specified VLAN.
Adding a New VLAN and Configuring the VLAN Querier Settings
1.
Open the MLD Snooping
VLAN Querier
page.
2.
Click
Add
.
The page refreshes, and the
Add VLAN
page displays.
Figure 7-90. Add VLAN Querier
3.
Enter the VLAN ID and, if desired, an optional VLAN name.
4.
Complete the fields on the page as needed.
5.
Click
Apply Changes
.
The VLAN Querier settings are modified, and the device is updated.
Displaying the MLD Snooping VLAN Querier Summary Table
1.
Open the MLD Snooping
VLAN Querier
page.
2.
Click
Show All
.
The
VLAN Querier Summary Table
displays.

Table of Contents

Other manuals for Dell PowerConnect 6224

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dell PowerConnect 6224 and is the answer not in the manual?

Dell PowerConnect 6224 Specifications

General IconGeneral
Switching Capacity128 Gbps
Forwarding Rate95.2 Mpps
Power Supply100-240 VAC, 50/60 Hz
RAM128 MB
Flash Memory32 MB
Layer SupportLayer 2/3
StackingUp to 12 units
Weight12.1 lbs
MAC Address Table Size16, 000
Jumbo Frame SupportUp to 9, 216 bytes
Operating Temperature0°C to 45°C
Storage Temperature-40°C to 70°C
Humidity10% to 90% (non-condensing)
Ports24 x 10/100/1000BASE-T
VLAN SupportYes (802.1Q)
Dimensions17.3 x 13.8 x 1.7 in (440 x 350 x 44 mm)