Page #15 background image
Electrical indicator
Condition Corrective Action
The indicator blinks
amber if the system
experiences an
electrical error (for
example, voltage out
of range, or a failed
power supply or
voltage regulator).
See the System Event Log or system messages for the specific issue.
If it is due to a problem with the power supply, check the LED on the
power supply. Re-seat the power supply by removing and reinstalling
it. If the problem persists, see Getting Help.
Temperature indicator
Condition Corrective Action
The indicator blinks
amber if the system
experiences a
thermal error (for
example, a
temperature out of
range or fan failure).
Ensure that none of the following conditions exist:
A cooling fan is removed or has failed.
System cover, cooling shroud, EMI filler panel, memory-
module blank, or back-filler bracket is removed.
Ambient temperature is too high.
External airflow is obstructed.
See Getting Help.
Memory indicator
Condition Corrective Action
The indicator blinks
amber if a memory
error occurs.
See the system event log or system messages for the location of the
failed memory. Reinstall the memory device. If the problem persists,
see Getting Help.
PCIe indicator
Condition Corrective Action
The indicator blinks
amber if a PCIe card
experiences an
error.
Restart the system. Update any required drivers for the PCIe card.
Re-install the card. If the problem persists, see Getting Help.
15

Table of Contents

Other manuals for Dell PowerEdge EL

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dell PowerEdge EL and is the answer not in the manual?

Dell PowerEdge EL Specifications

General IconGeneral
BrandDell
ModelPowerEdge EL
CategoryServer
LanguageEnglish

Related product manuals