134 Configuration: Disk Groups and Virtual Disks
Changing the RAID Controller Module Ownership of a Virtual Disk or a
Disk Group
You can change the RAID controller module ownership of a virtual disk or a
disk group.
You can change the RAID controller module ownership of a standard virtual
disk or a snapshot repository virtual disk. You cannot directly change the
RAID controller module ownership of a snapshot virtual disk because the
snapshot virtual disk inherits the RAID controller module owner of its
associated source virtual disk. Changing the RAID controller module
ownership of a virtual disk changes the preferred RAID controller module
ownership of the virtual disk.
During a virtual disk copy, the same RAID controller module must own both
the source virtual disk and the target virtual disk. Sometimes both virtual
disks do not have the same preferred RAID controller module when the
virtual disk copy starts. Therefore, the ownership of the target virtual disk is
automatically transferred to the preferred RAID controller module of the
source virtual disk. When the virtual disk copy is completed or is stopped,
ownership of the target virtual disk is restored to its preferred RAID controller
module. If ownership of the source virtual disk is changed during the virtual
disk copy, ownership of the target virtual disk is also changed. Under certain
operating system environments, it may be necessary to reconfigure the multi-
path driver before an I/O path can be used.
1
To change:
a
The RAID controller module ownership of a virtual disk—Go to
step 2.
b
The RAID controller module ownership of a disk group—Go to step 3.
2
To change the RAID controller module ownership of a virtual disk,
perform these steps:
a
Select the
Logical
tab.
b
Select the virtual disk.
c
Select
Virtual Disk
Change
Ownership/Preferred Path
.
Alternatively, you can right-click the virtual disk and select
Change
Ownership/Preferred Path
from the pop-up menu.
d
Select the RAID controller module.
book.book Page 134 Friday, September 23, 2011 2:46 PM

Table of Contents

Other manuals for Dell POWERVAULT MD3600F

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dell POWERVAULT MD3600F and is the answer not in the manual?

Dell POWERVAULT MD3600F Specifications

General IconGeneral
HDD speed15000 RPM
RAID levels0, 1, 5, 6, 10
Data transfer rate8 Gbit/s
Storage drive size3.5 \
Storage drive capacity600 GB
Storage drive interfaceSerial Attached SCSI (SAS)
Storage drives installedYes
Installed storage drive typeHDD
Supported storage drive typesHDD & SSD
Total installed storage capacity3.6 TB
Maximum supported storage capacity36 TB
Number of storage drives installed6
Number of storage drives supported12
Chassis type-
Product colorGray
LED indicatorsPower, Status
AC input voltage90-264 V
AC input frequency47/63 Hz
Number of power supply units1
Power supply unit (PSU) capacity600 W
Operating altitude-16 - 3048 m
Operating temperature (T-T)10 - 35 °C
Operating relative humidity (H-H)20 - 80 %
Weight and Dimensions IconWeight and Dimensions
Depth561 mm
Width446.3 mm
Height86.8 mm
Weight29300 g