Required tools / Herramientas necesarias
100% Silicone Sealant – Clear
Sellador de silicona 100 % - Transparente
Closed-Toe Shoes
Zapatos cerrados
1/8" Drill Bit
Broca de 1/8"
Marking Tool
Herramienta
de marcado
5/16" Drill Bit
Broca de 5/16"
1/4" Tile Bit
Broca de 1/4" para baldosas
3' Level or longer
Nivel de 3' o más largo
3" Deep Miter Box
Caja de ingletes de
3" de profundidad
32 TPI
32 TPI
Tin Snips
Tijeras para chapa fina
Cut Resistant Gloves with Non-Slip Grip
Guantes anticorte y antideslizantes
Safety Glasses
Gafas protectoras
Metal File
Lima de metal
Stud Finder
Detector de montantes
Painters Tape
Cinta de pintor
Shop Vacuum
Aspiradora de taller
Enclosure / Recinto
2-1/2"
distance
from sill to
center of stud.
Distancia
de 63,5 mm
desde el travesaño
hasta el centro
del montante.
Enclosure / Recinto
2-1/2"
distance
from sill to
center of stud.
Distancia
de 63,5 mm
desde el travesaño
hasta el centro
del montante.
CAUTION: Studs must be in this location on each side of door installation.
PRECAUCIÓN: Los montantes deben estar en esta ubicación a cada lado de la instalación de la puerta.
Enclosure / Recinto
2-1/2"
distance
from sill to
center of stud.
Distancia
de 63,5 mm
desde el travesaño
hasta el centro
del montante.
Enclosure / Recinto
2-1/2"
distance
from sill to
center of stud.
Distancia
de 63,5 mm
desde el travesaño
hasta el centro
del montante.
STUD LAYOUT / DISPOSITION DES MONTANTS
CAUTION:
To install your Delta shower door unit, you must:
Completely read all instructions, warnings, cautions, and
maintenance information. Failure to do so may result in
personal injury, property damage, or product failure, and
may void the warranty.
To reduce risk of personal injury, always wear eye
protection complying with ANSI standard Z87.1+ and cut
resistant gloves complying with EN388 with non-slip grip
when cutting, drilling and when handling glass and wear
closed toe shoes at all times during installation.
• Purchase the correct water supply components.
Ensure walls are within 3/8" of plumb (vertical) when
facing the front of the shower. Dimensions across the
top and bottom of shower should be within 3/8" of each
other.
PRECAUCIÓN:
Para instalar su unidad de puertas para ducha Delta, debe:
Leer por completo todas las instrucciones, advertencias,
einformación de mantenimiento. El no hacerlo podría provocar
lesiones personales, daños a la propiedad o fallas en el producto,
yademás se podría perder la garantía sobre el producto.
Para reducir el riesgo de lesiones personales, use siempre
protección de ojos que cumpla con la norma ANSI Z87.1 +,
guantes anticorte que cumplan con la norma EN388 y que sean
antideslizantes al momento de cortar, taladrar o manipular vidrio;
además use zapatos cerrados durante todo el tiempo que dure la
instalación.
• Adquiera los componentes de suministro de agua adecuados.
Asegúrese de que las paredes estén plomadas (vertical) a 3/8"
(9,52 mm). Las dimensiones en la parte superior e inferior de la
ducha deberían estar dentro de 3/8" (9,52 mm) el uno del otro.
Wall Surround / Anillo de pared Tile Surround / Anillo de azulejo

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Delta C500 and is the answer not in the manual?

Delta C500 Specifications

General IconGeneral
BrandDelta
ModelC500
CategoryPlumbing Product
LanguageEnglish

Related product manuals