Specifications
Enclosure
Operating temperature
Relative humidity
Galvanic isolation
Safety class
Overvoltage category
Flicker impedance
Three-phase combinations
Max. input voltage
Operating voltage range
MPP range (rated power)
Normal voltage
MPP tracker
Startup voltage
Input connection
Max. inverter backfeed
current to the array
Maximum input current
Max. short circuit current (per MPPT)
Operating Altitude
Environmental category
Pollution degree
Nominal output power
*2
Maximum power
Nominal output current
Maximum output fault current
Maximum output over current protection
Frequency
Total harmonic distortion
*3
Power factor *
3
Peak efficiency
EU efficiency
Output connection
Voltage
Max. output current
Current (inrush)
(A, peak and duration)
Housing
Cooling
IP rating
External communication
Weight
Dimensions
GENERAL
Model
*1
H2.5_210
H2.5_211
H3_210
H3_211
H3A_220
H3A_221
H4A_220
H4A_221
H5A_220
H5A_221
DC INPUT (Solar side)
AC OUTPUT (Grid side)
MECHANISM
REGULATIONS & DIRECTIVES
Safety
Grid interface
Harmonics
Immunity
Immunity
Emission
Variations and flicker
ESD
EFT
Surge
CS
PFMF
RS
Powder-coated aluminium
-25~60°C, full power up to 40°C
2000 m
0% – 95% non-condensing.
Outdoor, wet locations
No (TL Topology)
Class I metal enclosure with protective earth
Internal: II, External: III
AC output: III, DC input: II
Z = 0.4 + j 0.25 Ω (total impedance)
No
600 Vdc500 Vdc
350 Vdc
30-550 Vdc30-500 Vdc
240-500 Vdc240-470 Vdc 290-500 Vdc 180-500 Vdc
11 Adc for each /
18 Adc for total
11Adc for each/
22Adc for total
11 A
21
13.9 A
0 A
35 Vdc
MC4, 2 pairsMC4, 1 pair
230Vac -20%~+22%
30 A peak, 1 ms
50/60 Hz
<3% @Rated power
>0.99 @Rated power
97.5% 98.3%
98.0%96.8%
IP 67 single-phase
5000 VA4000 VA3000 VA2500 VA
22 A
Die casting
Convection cooling
IP65
Wi-Fi
12 kg11 kg10 kg
380 × 318 × 130 mm
IEC 61000-6-4, IEC 61000-6-3
EN 61000-6-2
IEC 61000-4-2
IEC 61000-4-3
IEC 61000-4-4
IEC 61000-4-5
IEC 61000-4-6
IEC 61000-4-8
IEC 62109-1 / -2, CE compliance
EN 61000-3-12
EN 61000-3-11
VDE AR-N 4105 / VDE 0126-1-1 / AS4777.2:2015 *
4-1
/ G83-2 / G59-3 /
EN50438 / VFR2014 / C10 / C11 / UTE C15-712-1 / IEC61683 / IEC61727 /
IEC62116 / EN50549-1:2019 / ABNT NBR 16149 *
4-2
/ ABNT NBR 16150
*4-2
5000 VA4000 VA3000 VA2500 VA
17.4 A13 A10.9 A
24 A18.6 A14.3 A13.9 A
25 A20 A16 A
25 A20 A16 A
*1: H2.5_210/ H3_210/ H3A_220/ H4A_220/ H5A_220/ H5A_222: The product is with DC switch
H2.5
_211/ H3_211/ H3A_221/ H4A_221/ H5A_221: The product is without DC switch
*2: (a) H2.5: 2.49kVA max. for Australia (AU / NZ)
(b) H3/ H3A: 2.99kVA max. for Australia (AU / NZ)
(c) H5A: 4.99kVA max. for Australia (AU / NZ)
(d) H5A: 4.6kVA max. for Germany (DE)
(e) H4A/ H5A: 3.68kVA max. for Denmark (DK1 / DK2)
*3: reactive power control disabled
*4-1: not support AS4777.2:2015 Single-phase inverters used in three-phase combinations
*4-2: Only H3
_210/ H4A_220/ H5A_220 support