8514-300-001 REV PR
Figure 7-37 Electrical Connecons
7.1.11.1 Installing the Electrical Connecons
1. Disconnect all power to the washer.
2. Remove the top panel of the washer and locate the power terminal block near the back
of the control compartment.
3. For 230V-1PH-50Hz, connect L1, N and Earth.
INFORMATION
SCCR for all washers is 5kA
7.1.11.2 Fusing Requirements
See specification sheet for required TIME-DELAY (DUAL ELEMENT) FUSE size (or equivalent
circuit breaker)
The installation must meet the electrical requirements of the country of installation. The installer
must provide a disconnect switch, which will interrupt all lines. It may be a local or national
requirement to provide an electrical interruption switch visible and accessible from the room in
which the washer is installed.
INFORMATION
It is important that the earthing screw next to
the power terminal block TB-1 be connected to
a good external earth.