Installation Diagrams - Introduction to Installation Diagrams 3 - 1
Introduction to Installation Diagrams
• The installation options listed on the following pages may or may not be reimbursable installations. Refer to the latest
Business Rules to confirm reimbursement status.
• Installations must use all Legacy LNBFs and switches, or all DISH Pro/DISH Pro Plus LNBFs and switches. Do not mix
and match Legacy components with DISH Pro/DISH Pro Plus components.
• If upgrading from Legacy LNBFs and switches to DISH Pro/DISH Pro Plus LNBFs and switches, ensure all Legacy
components (for example, power inserters) are removed. Remove DP Adapters from any Legacy receivers connected
to DISH Pro Plus components.
• Maximum distance between the furthest LNBF and farthest receiver is 200 feet for DP/DP Plus receivers; 100 feet for
Legacy receivers (four-digit model numbers). Maximum cable length from a wing dish with a compatible DISH Pro
LNBF to a DISH Pro Plus LNBF’s LNB I
N port is 80 feet with 120 feet from DPP LNBF to receiver for a total of 200 feet.
• Ensure all components (for example, cable, ground blocks, diplexers, splitters, line amps, barrel connectors, wall plates
and surge protectors) are rated for DISH Pro/DISH Pro Plus installations (rated to 2150 MHz and pass DiSEqC 22 KHz
tone—review the DISH Network Approved Accessories List), also referred to as DP compatible.
• Refer to the LNBFs and Switches and Dish Antennas sections for Legacy receiver installation considerations.
Abbreviations
• DP: DISH Pro
• DPP or DP Plus: DISH Pro Plus