SX1278 Wireless Module E32 Series User Manual
Copyright ©2012–2017, Chengdu Ebyte Electronic Technology Co., Ltd. 20 / 24
----------------------------------------------
5,4,3 TTL UART baud rate(bps)
000:1200bps
001:2400bps
010:4800bps
011:9600bps(default)
100:19200bps
101:38400bps
110:57600bps
111:115200bps
--------------------------------------------------
2,1,0 Air data rate(bps)
000:0.3Kbps
001:1.2Kbps
010:2.4Kbps(default)
011:4.8Kbps
100:9.6Kbps
101:19.2Kbps
110:19.2Kbps(same to 101)
111:19.2Kbps(same to 101)
-----------------------------------------------------------
UART baud rate can be different between
The UART baud rate has nothing to do with wireless
transmission parameters & won’t affect the
wireless transmit / receive features.
------------------------------------------------------------
The lower the air data rate, the longer the
transmitting distance, better anti-interference
performance and longer transmitting time
The air data rate must keep the same for both
7,6,5: N/A
------------------------------------------------
4-0:Communication channel(410M + CHAN*1M),
default 17H(433MHz)
--------------------------------------------------------
00H-1FH, correspond to 410~441MHz
7, Fixed transmission(similar to MODBUS)
0: Transparent transmission mode
1: Fixed transmission mode
----------------------------------------------------
6 IO drive mode(the default 1)
1:TXD and AUX push-pull outputs,
RXD pull-up inputs
0:TXD、AUX open-collector outputs,
RXD open-collector inputs
In fixed transmission mode, the first three bytes of
each user's data frame can be used as high/low
address and channel. The module changes its
address and channel when transmit. And it will
revert to original setting after complete the
process.
------------------------------------------------------------
This bit is used to the module internal pull-up
resistor. It also increases the level’s adaptability in
case of open drain. But in some cases, it may need
external pull-up resistor.