1
HIGH SPEED OVEN INSTALLATION INSTRUCTIONS
INSTALLATION AND SERVICE MUST BE PERFORMED BY A QUALIFIED INSTALLER.
IMPORTANT: SAVE FOR LOCAL ELECTRICAL INSPECTOR'S USE.
READ AND SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE.
The electrical requirements for this oven are 240 volts, 15 amps.
The oven has a 6-15 plug and requires a 6-15 receptacle.
Figure 1
TINSEB424MRR0 31613737
All dimensions are in inches (cm).
NOTE:
1. Base must be capable of supporting 200 pounds
(90.7 kg).
2. Make sure base is level and front of cabinet is
square. If the cabinet base is not level, the oven
will tend to slide out when opening the door.
3. Minimum required distance is 36" (91.44 cm) from
the floor.
4. At the rear of the opening, provide a 3 pronged,
polarized, electrical outlet, 240 volt A.C., 15 amp.
or larger. This outlet should not be located in the
shaded area of Figure 1. It is exceedingly important
that the outlet be 240 volts and 15 amps. for
optimum oven performance.
5. Minimum required distance between the high speed
oven and the wall oven should be 3-inches.
Printed in United States
PRODUCT DIMENSIONS
MODEL A B C D
30" (76.2) High Speed Oven 30" (76.2) 22
27
/
32
" (58.0) 21
1
/
4
"
(54.0) 22
15
/
16
" (58.2)
CUTOUT DIMENSIONS AND CABINET WIDTH
MODEL Min. F Max. G Min. H Max. I
30" (76.2) High Speed Oven 22
3
/
8
" (56.8) 22
5
/
8
" (57.5) 24" (61.0) min. 21
11
/
16
"(55.1) 21
15
/
16
"(55.7) 30" (76.2) min.
Important Notes to the Installer
1. Read all instructions contained in these installation instructions
before installing the high speed oven.
2. Remove all packing material from the oven compartments before
connecting the electrical supply to the high speed oven. Remove
the 2 shipping duct supports (see figure 1) by removing the 4
screws securing them. Reinsert 2 screws (each side) to secure
the stainless cover.
3. Observe all governing codes and ordinances.
4. Be sure to leave these instructions with the consumer.
Important Note to the Consumer
Keep these instructions with your Owner's Guide for future
reference.
B
A
(53.9 cm)
21
7
/32"
16
3
/4"
20
1
/4"
D
C
F
I
H
G
Remove 2 duct
shipping supports
(both sides)
C
L
Replace these
screws after
shipping support
removal (both sides)