Optional – Job Storage
Alignment jobs can also be saved and printed.
This is found under “Job Manager” on the ALT screen
of the main menu.
You can customize
the machine
graphics using a
selection of
different machine
types. Consult the
user manual for
additional details,
advanced functions,
and instructions.
Pocket Guide
For Laser Shaft Alignment
AMS 2140
Machinery Health
™
Analyzer
Refer to the user
manual to learn
how to upload
saved jobs back to
the PC software.
Introduction:
This guide outlines a quick and easy 3-step
method for precision shaft alignment.
Set-up:
Choose the shortest support posts that will still
allow the laser beam to pass over or through the
coupling. Mount the laser xtures by sliding each
head over the support posts and locking them
into place with the yellow clamping levers.
Mount laser heads as shown above, being careful
to mount the laser on the stationary machine.
Sweep Size:
The “Auto Sweep” method provides a simple,
accurate solution for any alignment task. Start
anywhere. Stop anywhere. While it is always best
to completely rotate the shaft, this method can
be used effectively with partial sweeps down to
45°. Press [ENTER] to retrieve data via Bluetooth.
45°
Operating Notes:
Laser fixtures are for shaft alignment only and
should be operated by properly trained personnel.
As precision instruments, care should be taken to
not subject them to shock.
Laser Safety:
Do not stare directly into the laser beam!
[NOTE: Red LED on Laser Head indicates that
laser is active.]
Do not insert optical
devices into beam.
P/N: MHM-97109, rev 1
Mount laser on
stationary machine
Mount sensor on
machine to be moved
AMS 2140 Machinery Health
™
Analyzer