Setting up passwords (PASSWRD)Figure 6-13:
6.10.1 Lock meter setup parameters
Enter the Password menu, select Pass, and program a five-digit password. The meter will
return to Run mode after locking any of the passwords.
For instructions programming numeric values see Section 5.3.
Locking meter setup parametersFigure 6-14:
6.10.2 Reset total and grand total on a password protected
meter
If the meter is password protected for total or grand total reset, the meter will display the
message PASS T or PASS GT when an attempt is made to enter the password protected
total or grand total Reset menus. Input the password and press the Enter button to reset
the total or grand total.
The password requirement may be disabled by entering the password in the Password
menu for total (PASS T) or grand total (PASS GT).
6.10.3
Disable password protection
To disable the password protection, access the Password menu, select the type of
password to be disabled, and enter the correct password as shown below. That password is
now disabled until a new password is entered.