Configuration Menu
Menu Number Feature and selection Default Value
Press up or down
to select
1
Sensor Selection
A = Air sensing using built in sensor
AR = Air sensing using remote air sensor
FR = Floor sensing using remote floor temperature
AF = Air sensing for setpoint, floor sensing for safety cut off
A A / AR / FR / AF
2
Program selection
5_2 = 5 days (Mon - Fri)
time/temperature settings and 2 days (Sat - Sun)
time/temperature settings
7_0 = 7 days
individual day settings or whole week settings
7_0 5_2 / 7_0
3
Switching differential
The number of degrees difference between switching
off at the set temperature and on again to reach the set
temperature i.e. a 1
o
C setting will switch the thermostat
on 0.5
o
C below the setpoint and switch the thermostat off
0.5
o
C above the setpoint
1
o
C 1
o
C - 5
o
C
4
Thermostat calibration (AIR)
By adjusting this figure any discrepancy between displayed
air temperature and measured air room temperature can be
offset
0
o
C -5
o
C ~ + 5
o
C
5
Thermostat calibration (FLOOR)
By adjusting this figure any discrepancy between displayed
floor temperature and measured floor temperature can be
offset
0
o
C -5
o
C ~ + 5
o
C
6
Optimum start
Ensures that the required setpoint is reached prior to the
ON time setting
OFF ON / OFF
7
Set floor temperature limit
Provides floor temperature protection when using AF
function
40
oC
20
o
C - 40
o
C
8 Select 12/24 hour clock 24 12 / 24
9
Select backlight option
ON/ OFF after 30 seconds.
ON ON/ 30 seconds
10
Frost protection
Set to ON to maintain a room temperature above 5°C in the
event of severe low temperatures
OFF ON/ OFF
Hidden Menu
11 Limit minimum setpoint 10
o
C 10
o
C - 20
o
C
12 Limit maximum setpoint 35
o
C 15
o
C - 35
o
C
13 Factory Reset
Hold ‘down’
arrow for 5
seconds