EasyManuals Logo
Home>emmeti>Control Unit>EWC-2

emmeti EWC-2 User Manual

emmeti EWC-2
2 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
4
ALP03M0001MB 023312D4 250314
centre e.g. a circulating pump.
Terminals L2 and N2 are the 230V~ powered
outputs for connecting the circulating pump.
Terminals NO and C are the output for the boiler
control. This is a voltage free contact (i.e.
unpowered) so that they can be used for boilers
with different voltages.
Through terminals L1 N1 SWL NSB a 230V~
external timeswitch (optional) can be connected to
the wiring centre. Terminals L1 and N1 are the
powered outputs for the timeswitch power supply,
while SWL and NSB are the lines provided for
powering the actuators and thermostats section.
For complete control of each of the available
channels the user must connect a 230V~ actuator
to terminals L1 and N1 and a 230V~ thermostat to
terminals NSB SwL< SwL> TN TL. All outputs of
the actuators and thermostats section are 'powered'
outputs, i.e. they do provide the voltage for the
device connected to them.
Note: Each of the eight wiring channels has
t
erminals for one thermostat and one actuator only.
Up to five actuators can be connected to a channel
by using a loose cap terminal, code U9360030,
available from Emmeti UK Ltd.
TECHNICAL FEATURES
Power supply: 230V~ ±10% 50Hz
Absorption: Depends on the loads
connected.
Fuse (F1): 8A Time delayed
Pump output: Powered contact
Boiler output: Voltage free contact
Therm./actuators outputs: 230V~
Time prog. output (optional): 230V~
Contacts rating:
- Pump: 5A@250V~ SPDT
- Boiler: 1A@250V~ SPDT
- Actuators and thermostats: 8x1A@250V~
Maximum applicable load
:
- Actuators and thermostats: 2,5A Total
1A each channel
Indicators:
- Voltage presence: Green led
- Boiler and pump activation: Red led
Protection index:
Operating temp.:
Storage temp.:
Humidity limits':
Case: Material:
Colour:
Dimensions:
Weight:
IP 30
0 .. 40 °C.
-10 .. 50 °C
20% .. 80% RH
(non condensing)
ABS UL-V0
self-extinguishing
Signal white
(RAL 9003)
245 x 100 x 60 mm
(W x H x D)
~ 520 gr.
WARRANTY
In view of the constant development of their
products, the manufacturer reserves the right for
changing technical data and features without prior
notice. The consumer is guaranteed against any
lack of conformity according to the European
Directive 1999/44/EC as well as to the
manufacturer’s document about the warranty policy.
The full text of warranty is available on request from
the seller.
1
ALP03M0001MB 023312A4 250314
U9370001
EWC-2 8 WAY WIRING CENTRE 230V
230V~ power supply and outputs
Connections for up to 8 separate heating zones
Pump output and interlock boiler output
Each channel has terminals for one thermostat and actuator
External timeswitch input (optional)
Compliant with directives EEC 2004/108 (EMC), 2006/95 (LVD)
and 2011/65 (RoHS2)
6 Tannery Yard - Witney Street - Burford
Oxfordshire - OX18 4DW - UK
Phone: 01993 824900
Fax: 01993 824990
Email: sales@emmeti.co.uk
Website: www.emmeti.co.uk
UK
Fig. 3: Cable entry instructions
Fig. 1: External aspect
Fig. 2: Internal view and parts
2
2
226 mm
245 mm
100 mm
11 mm
55 mm 26,5 mm
3
4
Wiring Centre
EWC-2 8-Way
1
1 1 1
1
B A

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the emmeti EWC-2 and is the answer not in the manual?

emmeti EWC-2 Specifications

General IconGeneral
Brandemmeti
ModelEWC-2
CategoryControl Unit
LanguageEnglish