Technical Information
TI 350F/00/en
Level Limit Switch
nivotester FTL 325 P
With intrinsically safe signal circuit for connection to
the Liquiphant and Soliphant measuring sensor
Applications
Level limit detection in liquid tanks and
bulk material silos, also in hazardous
explosion areas
For Zone 0 or Zone 20 measuring
sensors
Liquid detection in pipes for dry
running protection for pumps
Overspill protection for tanks with
combustible or non-combustible
liquids harmful to water
Two-point control and level limit
detection with one switching instrument
Application in safety related systems
with requirements for functional safety
up to SIL3 in accordance to IEC 61508
when using Liquiphant M/S with
electronic insert FEL 57
Benefits at a glance
Intrinsically safe signal circuits [EEx ia]
for problem-free use of measuring
sensor in explosion hazardous areas
Highest functional SIL safety (see also
Safety Manual SD 111) through:
fault-free PFM technology
line monitoring through to sensor
corrosion monitoring on tuning fork of
Liquiphant M measuring sensor
Compact housing for simple series
installation on standard rails in switch
cabinet
Simple wiring using pluggable terminal
blocks
Simple iterative test acc. to WHG by
connecting a Liquiphant M and S (high
temperature): one-touch operation
High test depth: from isolating amplifier
through to measuring sensor

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Endress+Hauser nivotester FTL 325 P and is the answer not in the manual?

Endress+Hauser nivotester FTL 325 P Specifications

General IconGeneral
BrandEndress+Hauser
Modelnivotester FTL 325 P
CategorySwitch
LanguageEnglish

Related product manuals