FALSE ALARM CONTROL
Models GC240, I240C, PADC240, PG240, PAR230, FADC230 and IAR230C feature False
Alarm Control that, when activated, quiets unwanted alarms for up to 15 minutes.
To use the False Alarm Control:
Press and release the test button during an unwanted alarm. The alarm should
stop within ten seconds. This means the smoke alarm is in False Alarm Control.
If the smoke alarm does not go into False Alarm Control and continues to sound
its loud alarm horn, or if it initially goes into False Alarm Control then resounds the
alarm, the smoke is too heavy and could be a dangerous situation— take emer-
gency action.
TESTING THE SMOKE ALARM
W ARNING
•
Test each smoke alarm to be sure it is installed correctly and operating properly.
•
Test all smoke alarms in an interconnected system after installation.
•
The Push-to-Test button accurately tests all functions. DO NOT use an open
flame to test this smoke alarm. You may ignite and damage the smoke alarm or
your home.
•
Test smoke alarms weekly and upon returning from holiday or when no one has
been in the household for several days.
•
Stand at arm’s length from the smoke alarm when testing. The alarm horn is
loud to alert you to an emergency and can be harmful to hearing.
Test all smoke alarms weekly by doing the following:
1. Check Push-to-Test button. A constant green light indicates the smoke alarm is
receiving 230V AC, 50Hz power. A red flashing LED about once a minute veri-
fies operation. For models I240C, PAD240, PADC240, FADC230, IAR230C, and
PAR230 the red flashing LED also verifies that a working battery is present.
2. Firmly depress the Push-to-Test button for at least five (5) seconds. The smoke
alarm will sound a loud beep about four (4) times a second. The alarm may
sound for up to 10 seconds after releasing the Push-to-Test button.
NOTE: If smoke alarms are interconnected, all smoke alarms should sound an
alarm within three seconds after any test button is pushed and the tested
smoke alarm sounds.
3. If smoke alarm does not sound, turn off power at main fuse box or circuit
breaker and check wiring. Retest smoke alarm.
DANGER: If alarm horn sounds, and smoke alarm is not being
tested, the smoke alarm is sensing smoke. THE
SOUND OF THE ALARM HORN REQUIRES YOUR
IMMEDIATE ATTENTION AND ACTION.
MAINTENANCE AND CLEANING
In addition to weekly testing, Models I240C, PAD240, FADC230, and PADC240 also
require periodic battery replacement. Regularly clean smoke alarm to remove dust, dirt,
and debris.
WARNING: Alarm comes equipped with a dust cover, which
prevents dust and debris from damaging the unit
during construction or remodeling. Remove dust
cover before operation. Alarm will not operate
properly while covered.
DANGER: ELECTRICAL SHOCK HAZARD. Turn off main power
at fuse box or consumer unit by removing fuse or
switching appropriate circuit breaker to OFF position
before replacing battery or cleaning smoke alarm.
BATTERY REPLACEMENT
(For Models I240C, PADC240, FADC230, and PAD240 only):
CAUTION: Danger of explosion if battery is incorrectly replaced.
Always turn off power to smoke alarm before replacing battery. Replace battery at
least once a year or immediately when the low battery signal sounds once a minute,
even though the smoke alarm is receiving AC power.
Use only the following batteries as replacements in this smoke alarm:
Eveready 216, 522, 1222; Duracell MN 1604; or Ultralife U9VL-J
Replace only with the same or equivalent battery type recommended by the manu-
facturer. Discard used batteries safely according to manufacturer's instructions.
TEST THE ALARM FOR CORRECT OPERATION USING THE TEST BUTTON
WHENEVER THE BATTERY IS REPLACED.
WARNING: DO NOT USE ANY OTHER TYPE OF
BATTERY, EXCEPT AS SPECIFIED IN THIS MANUAL.
DO NOT USE RECHARGEABLE BATTERIES.
(For Models IAR230C and PAR230 only):
NOTE: Rechargeable lithium batteries are permanently mounted and sealed in
the tamper-proof housing. These cells are designed to last the useful life
of the smoke alarm. The batteries are not replaceable.
For Models I240C, PAD240 and PADC240 Only:
1. Turn off power to smoke alarm at main service panel.
2. Insert a small screwdriver into the slot in the mounting plate. Depress locking
tab with the screwdriver and turn smoke alarm counter-clockwise to detach
from mounting plate.
3. Gently pull down smoke alarm. Be careful not to separate wire connections.
4. Pull out power plug from back of smoke alarm.
5. From back of smoke alarm, lift tab to open battery pocket door.
6. Remove battery from pocket. Disconnect and discard drained battery from
battery connector.
7. Connect a fresh, 9-volt battery to connector. The battery will fit only one way.
Be sure battery connector is securely attached to battery terminals. Smoke
alarm may sound a short beep when battery is installed. This is normal and
means the battery is installed correctly.
8. Place battery into battery pocket.
9. Close battery pocket door. Push down until it snaps into place.
10. Press and hold test button. The alarm will sound if the battery is properly con-
nected and working.
11. Replace connector plug. Connector will “snap” into place. Gently tug con-
nector to be sure it is attached properly.
12. Reattach smoke alarm to mounting plate by turning smoke alarm clockwise
until it snaps into place.
13. Turn on power and test smoke alarm using test button.
For Model FADC230 Only:
1. Turn off power to smoke alarm at main service
panel.
2. Slide battery door open as shown in the illustration.
3. Remove drained battery from compartment and dis-
card.
4. Install a fresh 9-volt battery.
5. Slide battery door closed.
6. Turn on power and test smoke alarm using Push-to-
Test button.
CLEANING
Clean the smoke alarm at least once a month to remove dust, dirt, or debris. Always
turn off power to smoke alarm before cleaning.
•
Using the soft brush or wand attachment to a vacuum cleaner, vacuum all sides
and cover of smoke alarm. Be sure all the vents are free of debris.
•
If necessary, turn off power and use a damp cloth to clean smoke alarm cover.
IMPORTANT: Do not attempt to remove the cover or clean inside the smoke alarm.
THIS WILL VOID YOUR GUARANTEE.
REPAIR
CAUTION: Do not attempt to repair this smoke alarm. Doing so will
void your guarantee.
If smoke alarm is not operating properly, see “Troubleshooting”. If necessary and if
still under guarantee, return smoke alarm to Sensotec. Pack it in a well-padded
carton and send, postage prepaid to Sensotec address at the end of this manual.
If the smoke alarm is no longer under guarantee, have a licensed electrician
replace the smoke alarm immediately with a comparable Firex brand smoke alarm.
PRACTICE FIRE SAFETY
If the smoke alarm sounds its alarm horn, and you have not pushed the test
button, it is warning of a dangerous situation. Your immediate response is nec-
essary. To prepare for such occurrences, develop family escape plans, discuss
them with ALL household members, and practice them regularly.
•
Expose everyone to the sound of a smoke alarm and explain what the
sound means.
•
Determine TWO exits from each room and an escape route to the outside
from each exit.
•
Teach all household members to touch the door and use an alternate exit if
the door is hot. INSTRUCT THEM NOT TO OPEN THE DOOR IF THE
DOOR IS HOT.
•
Teach household members to crawl along the floor to stay below danger-
ous smoke, fumes, and gases.
•
Determine a safe meeting place for all members outside the building.
WHAT TO DO IN CASE OF A FIRE
1. Don’t panic; stay calm.
2. Leave the building as quickly as possible. Touch doors to feel if they are
hot before opening them. Use an alternate exit if necessary. Crawl along
the floor, and DO NOT stop to collect anything.
3. Meet at a pre-arranged meeting place outside the building.
4. Call the fire brigade from OUTSIDE the building.
5. DO NOT GO BACK INSIDE A BURNING BUILDING. Wait for the fire
brigade to arrive.
These guidelines will assist you in the event of a fire. However, to reduce the
chance that fires will start, practice fire safety rules and prevent hazardous sit-
uations.
TROUBLESHOOTING
DANGER: Always turn off power at main fuse box or consumer
unit before taking trouble- shooting action.
WARNING: DO NOT disconnect battery or mains power to
quiet an unwanted alarm. This will remove your
protection. Fan the air or open a window to
remove smoke or dust. For Models GC240, I240C,
PADC240, PG240, PAR230, FADC230 and IAR230C
you may also use the False Alarm Control feature
to quiet unwanted alarms.
WARRANTY
Maple Chase warrants to the original consumer purchaser each new smoke
alarm to be free from defects in material and workmanship under normal use
and service for a period of six (6) years in the United Kingdom and Republic
of Ireland from date of purchase. Maple Chase agrees to repair or replace, at
its option, any defective smoke alarm, provided that it is returned with postage
prepaid and with proof of purchase date to Maple Chase. This warranty does
not cover damage resulting from accident, misuse or abuse or lack of reason-
able care of the product. This warranty is in lieu of all other express warranties,
obligations or liabilities. THE IMPLIED WARRANTIES OF MERCHANTABILITY
AND FITNESS FOR A PARTICULAR PURPOSE ARE LIMITED TO A PERIOD
OF SIX (6) YEARS FROM PURCHASE DATE. Some states do not allow
limitations on how long an implied warranty lasts, so the above limitations may
not apply to you. IN NO CASE SHALL MAPLE CHASE BE LIABLE FOR ANY
INCIDENTAL OR CONSEQUENTIAL DAMAGES FOR BREACH OF THIS OR
ANY OTHER WARRANTY, EXPRESS OR IMPLIED, WHATSOEVER, EVEN IF
THE LOSS OR DAMAGE IS CAUSED BY ITS NEGLIGENCE OR FAULT. Some
states do not allow the exclusion or limitation of incidental or consequential
damages, so the above limitation or exclusion may not apply to you. This
warranty gives you specific legal rights, and you may also have other legal
rights which vary from state to state.
Return units freight prepaid to your local reseller. For information on your local
reseller in the U.K. and Republic of Ireland, contact:
Sensotec Europe Ltd.
Unit 7, Bala Industrial Estate
Bala, Gwynedd LL23 7NL
United Kingdom
Tel.: +44 (0) 1678 520022
Fax.: +44 (0) 1678 520689
5 6 7 8
!
!
!
!
!
!
!
!
!
PROBLEM SOLUTION
Smoke alarm does not 1. Check that AC power
sound when tested. is turned on. Green LED
should be illuminated.
2. Turn off power. Remove
smoke alarm from
mounting plate and:
a. check that connector
plug is securely
attached.
b. check that battery is
properly attached to
connector.
3. Clean smoke alarm.
Smoke alarm beeps about 1. Turn off power and
once a minute. replace battery. See
(Models I240C and Battery Replacement”
PAD240 only) in the MAINTENANCE
AND CLEANING section.
2. Clean smoke alarm.
(Models IAR230C and 3. Verify that unit has been
PAR230) under mains operation
for a minimum of 2 full
days. If the beeping
persists after required
charging period, return
the unit for service.
Smoke alarm sounds 1. Hire an electrician to
unwanted alarms when move smoke alarm to a
residents are cooking, new location. See
taking showers, etc. "SMOKE ALARM
PLACEMENT"
Interconnected smoke 1. Press and hold test
alarms do not sound when button for at least
system is tested. three seconds after the
first unit sounds.
2. Hire an electrician to
ensure smoke alarms
are properly connected.
NOTE: Push test but-
ton for at least five (5)
seconds while testing!
Maple Chase
191 E. North Avenue
Carol Stream Illinois 60188 USA
www.maplechase.com
©2002 Maple Chase 111-276C
Manufactured by: