The new Fluke 87V has improved measurement functions, trouble-
shooting features, resolution and accuracy to solve more problems
on motor drives, in plant automation, power distribution, and electro-
mechanical equipment. The 87V operates very similar to the classic
87, but with more problem-solving power, safety, convenience and
impact protection.
Features for maximum productivity
•
Unique function for accurate voltage and frequency measurements
on adjustable speed motor drives and other electrically noisy
equipment (87V)
•
Built-in thermometer conveniently allows you to take temperature
readings without having to carry a separate instrument (87V)
•
Large digit display with bright, two-level backlight makes the
80 Series V significantly easier to read than older models
NEW! 87V/E2 Industrial Electrician Combo Kit makes troubleshooting
more productive with standard meter hanging accessory for hands-
free operation, soft case for protection and storage, 1.5 m
heat resistant silicone test leads and more.
Electrical safety
All inputs are protected to Category III, 1000 V and Category IV
600 V. They can withstand impulses in excess of 8,000 V and
reduce risks related to surges and spikes.
Function Range and resolution Basic accuracy
83V 87V
DC Volts 600.0 mV, 6.000 V, 60.00 V,
600.0 V, 1000 V
0.1 % 0.05 %
AC Volts 600.0 mV, 6.000 V, 60.00 V, 0.5 % 0.7 %
600.0 V, 1000 V (True-rms)
DC Current 600.0 µA, 6000 µA, 60.00 mA,
600.O mA, 6.000 A, 10.00 A
0.4 % 0.2 %
AC Current 600.0 µA, 6000 µA, 60.00 mA, 1.2 % 1.0 %
600.O mA, 6.000 A, 10.00 A (True-rms)
Temperature -200 to 1090 °C (-328 to 1994 °F) — 1.0 %
(excl. probe)
80BK Temperature -40 to 260 °C (-40 to 500 °F) — 2.2 °C
Probe or 2 %
Resistance 600.0
W, 6.000 kW, 60.00 kW,
600.0 kW, 6.000 MW, 50.00 MW
0.4 % 0.2 %
Capacitance 10.00 nF, 100.0 nF, 1.000 µF,
10.00 µF, 100.0 µF, 9,999 µF
1.0 % 1.0 %
Frequency 199.99 Hz, 1.9999 kHz,
19.999 kHz, 199.99 kHz
0.005 % 0.005 %
80 Series V Industrial
True-RMS Multimeter
with Temperature
Specifications
Accuracy and diagnostic functions for
maximum industrial productivity