EasyManuals Logo

Frigidaire FCS388WHCD User Manual

Frigidaire FCS388WHCD
40 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
INSTALLATION AND SERVICE MUST BE PERFORMED BY
A QUALIFIED INSTALLER.
IMPORTANT: SAVE FOR LOCAL ELECTRICAL INSPECTOR'S USE.
READ AND SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE.
If the information in this manual is not followed exactly, a fire or explosion may
result causing property damage, personal injury or death.
FOR YOUR SAFETY:
-- Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other
appliance.
m WHATTO DO IFYOU SMELLGAS:
Do not try to light any appliance.
Do not touch any electrical switch; do not use any phone in your building.
Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions.
If you cannot reach your gas supplier, call the fire department.
Installation and service must be performed by a qualified installer, service agency or the gas supplier.
Do not pinch the power supply cord or the flexible gas
conduit between the range and the wall.
Do not seal the range to the side cabinets.
**NOTE: 30" (76.2 cm) minimum clearance between the
cooktop and the bottom of the cabinet when the bottom
of wood or metal cabinet is protected by not less than ¼"
(0.64 cm) flame retardant millboard covered with not less
than No. 28 MSG sheet metal, 0.015" (0.4 mm) stainless
steel, 0.024" (0.6 mm) aluminum, or 0.020" (0.5 mm)
copper.
36" (91.4 cm) minimum clearance when the cabinet is
unprotected.
NOTE: Allow at least 19 ¼" (48.9 cm) clearance for door
depth when it is open.
Door Open
(see note)
ulator
Shave Raised
Edge to Clear
30" (76.2 cm)
Wide Cooktop
Rim1 Y2" Max.
(3.8 cm Max.
Locate Cabinet
Doors 1" (2.5
cm) Min.
from Cutout
Opening.
*Note: 29"
(73.7 cm) Wide
Opening for
Overlapping
Cooktop and
Built-in Look.
If Installing Model With
Optional Side Panels,
Cutout Area Including
Countertop Must Be At
Least 30" (76.2 cm) Wide.
30" Min.
(76.2 cm Min.
18" Min.
cm) Min.
Grounded Jonction Box or Wall
Outlet Should Be Located 8"
to 17" (20.3 cm to 43.2 cm)
From Right Cabinet and 2" to
4" (5.1 cm to 10.2 cm) From
Floor.
22 7/8"
13"
3 cm)
24" Min.
(61 cm Min.)
35 3/8" (90 cm) - 30" 26 1/4"
36 3/8" (92 cm) (76.2 cm) (66.7 cm)
29" 21 3/4" 36" (91.4 cm) standard
(73.7 cm) (55.2 cm) 35 3/8" (90 cm) min.
ol 1/8"
(45.7 cm)
FRONT
G R_,.
OF
CABINET
G. Minimum Cutout Depth is increased to 24" (61 cm) with backguard.
NOTE: Wiring diagram for these appliances are enclosed in this booklet.
P/N 318201650 (0201) Rev. C
English - pages 1-12
EspaSol - p_tginas 13-24
Fran_ais - pages 25-36
Wiring Diagrams - pages 37-40