2018 Fujikura Ltd.
How to set to rotate the blade automatically by detecting worn blade
Bluetooth communication between Fujikura fusion splicers and cleavers provides a useful
function.
Cleaver blade rotates automatically by detecting worn blade.
This document shows example in case of 41S and CT50 combination.
1. Open Bluetooth setting menu and set [Splicer] and [Cleaver] to ON
2. Cleaver setting window appears in READY screen. If not appears, turn off and restart.
3. Open Bluetooth setting menu and pair with CT50
4. Set each [Blade Position Change], [Blade Height Change] and [Blade Replacement] to
ON.
SPLICING TIPS
No.6004
Nov-2018

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujikura CT50 and is the answer not in the manual?

Fujikura CT50 Specifications

General IconGeneral
ModelCT50
Fiber Count1
CategoryFiber Cleaver
Cleaving Angle CapabilityTypically less than 0.5 degrees
Fiber Holder CompatibilityFH-70 series fiber holders
Blade LifeUp to 60, 000 cleaves
WeightAbout 500g
Applicable Optical FiberSingle fiber
Cladding Diameter125 μm
Coating Diameter250 μm / 900 μm
Cleave Length5 to 20 mm
Typical Cleave AngleTypically less than 0.5 degrees