14. Function settings
To adjust the functions of this product according to the installation environment, various types of
function settings are available.
NOTE:
Incorrect settings can cause a product malfunction.
14-1. Indoor unit (setting by jumper wire)
NOTE: This setting is necessary only for slim duct type.
¢ Component location
¢ Jumper wire setting
Drainage function setting (JM1)
JM1 Function Factory setting
Connect Enable ♦
Disconnect Disable
Auto louver grille setting (JM2)
When optional Auto louver grille kit is attached, set this setting to "Valid".
JM2 Function Factory setting
Connect Disable ♦
Disconnect Enable
Fan delay setting (JM3)
JM3 Function Factory setting
Connect Disable ♦
Disconnect Enable
- 128 -
14-1. Indoor unit (setting by jumper wire) 14. Function settings
MULTI TYPE
2, 3, 4 ROOMS TYPE
MULTI TYPE
2, 3, 4 ROOMS TYPE