UAIS TRANSPONDER FA-100
Operator’s Guide
The purpose of this Operator's Guide is to provide basic operating procedures for this equipment. For
more detailed information see the Operator's Manual.
Turning on and off
· Press POWER key.
After self-test, the plotter display appears.
[- - - - - -]
SOG:
- - -.- kt
COG:
- - -.- deg
INTRD: 0
[
]: FWD
[
]: BACK
RNG: 1.50
n
m
Adjusting brilliance and contrast
1. Press CLR/ALT and SFT keys together.
BRILLIANCE
CONTRAST
ESC: [ENT]
2. Press ▲ or ▼ to adjust brilliance; ◄or ► to
adjust contrast.
3. Press ENT key.
Setting up for a voyage
Enter at the start of a voyage: draught,
destination, navigation, status, etc.
1. Press MENU, [5], and [1] key in that order.
+
-
123
[SET SHIP DATA]
DRAUGHT: 07.5 m
DTE : KEY & DISP
2. DRAUGHT is selected; enter ship's current
draught.
3. Press ENT, and then [2] key.
[SET DESTINATION]
DATE:00/00 (DD/MM)
TIME:00:00
DESTINATION:
NONE
4. Press NEXT to choose DATE, TIME or
DESTINATION and enter estimated date/time
of arrival or destination waypoint.
5. Press ENT, and then [3] key.
STATUS NAME
[SET STATUS]
NAV STATUS: 00
UNDER WAY USING
ENGINE (DEFAULT)
6. Press ▲, ▼, ◄ or ► key to choose
appropriate navigation status.
7. Press ENT, and then [4] key.
TYPE NAME
[SET TYPE&CREW]
CREW : 0012
TYPE CLASS : A
TYPE NO. : 0
+
-
8. CREW is selected; enter number of crews.
9. Press NEXT to choose TYPE NO. and press
arrow keys to choose appropriate type
number.
▲, ▼ : Increment, decrement by 1
◄, ►
: Increment, decrement by 10
10. Press ENT and MENU in that order.
SAVE ?
YES
NO
CANCEL
11. YES is selected; enter ENT.
Setting CPA/TCPA
1. Press MENU, [5], and [5] key in that order.
[SET CPA/TCPA]
CPA: 0.90 nm
TCPA: 01 min
ACTV: DSBL
+
-
2. Enter CPA and press NEXT.
3. Enter TCPA and press NEXT.
4. Press SFT to choose ENBL to activate the
CPA/TCPA alarm; DSBL to disable it.
5. Press ENT, MENU and ENT in that order.
Enabling/Disabling buzzer
1. Press MENU, [6] and [5] key in that order.
[SET BUZZER]
ALARM : ON
CPA/TCPA : ON
MSG ALM : ON
+
-
+
-
+
-
2. Press SFT to choose ON or OFF for each item.
ALARM: for system trouble
CPA/TCPA: for CPA/TCPA alarm
MSG ALM: for incoming message