7
Service Manual
Technical Information
Parameter Unit Value
Model AEE24KP
Product Code CC052006200_K93320
Power
Supply
Rated Voltage V~ 220
Rated Frequency Hz 60
Phases 1
Cooling Capacity W 6530
Heating Capacity W /
Cooling Power Input W 2350
Heating Power Input W /
Cooling Power Current A 10.8
Heating Power Current A /
Rated Input W 2700
Rated Current A 14.59
Air Flow Volume (H/M/L) m
3
/h 940/890/840
Dehumidifying Volume L/h 2.8
EER W/W 2.78
COP W/W /
Application Area m
2
27-42
Climate Type T1
Isolation I
Moisture Protection IP24
Permissible Excessive Operating Pressure for
the Discharge Side
MPa 3
Permissible Excessive Operating Pressure for
the Suction Side
MPa 1.5
Dimension (WXHXD)
mm 660X428X770
Dimension of Carton Box (LXWXH) mm 736X860X500
Dimension of Package (LXWXH) mm 739X863X515
Net Weight kg 68
Gross Weight kg 73
Refrigerant R22
Refrigerant Charge kg 1.4