EasyManuals Logo
Home>GE>Microwave Oven>JVM6175EK

GE JVM6175EK User Manual

GE JVM6175EK
3 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #2 background imageLoading...
Page #2 background image
Listed by
Underwriters
Laboratories
JVM6175SK/EK
GE Appliances 1.7 cu. ft. Over-the-Range Sensor Microwave Oven
Specification Created 2/16
Filler Panel Kit JX36CSS and
JX36CES
When replacing a 36" range
hood, this kit fills in the additional
width to provide a custom built-in
appearance. For installation
between cabinets only;
not for end-of-cabinet
installation. Each kit
contains two 3"-wide
filler panels.
Filter Kit JX81J–
Recirculating
Charcoal Filter Kit
To be used when
the microwave oven
cannot be vented
to the outside.
For answers to your Monogram, GE Café
Series, GE Profile
Series or
GE Appliances product questions, visit our website at geappliances.com
or call GE Answer Center
®
Service, 800.626.2000.
HOOD EXHAUST DUCT: Outside ventilation requires a HOOD
EXHAUST DUCT. Read the following carefully.
EXHAUST CONNECTION: The hood exhaust has been designed to mate
with a standard 3-1/4" x 10" rectangular duct. If a round duct is required, a
rectangular-to-round transition adaptor must be used. Do not use less than a
6" diameter duct
REAR EXHAUST: If a rear or horizontal exhaust is to be used, care should be
taken to align exhaust with space between studs, or wall should be prepared
at the time it is constructed by leaving enough space between the wall studs to
accommodate exhaust.
MAXIMUM DUCT LENGTH: For satisfactory air movement, the total duct
length of 3-1/4" x 10" rectangular or 6" diameter round duct should not exceed
140 equivalent feet.
ELBOWS, TRANSITIONS, WALL AND ROOF CAPS, etc., present
additional resistance to airflow and are equivalent to a section of straight
duct which is longer than their actual physical size. When calculating the total
duct length, add the equivalent length of all transitions and adaptors plus the
lengths of all straight duct sections. The chart below shows the approximate
feet of equivalent length of some typical ducts.
DUCT EQUIVALENT FEET
A. Rectangular-To-round
Transition Adaptor 5 ft.
B. Wa l l Cap 40 ft.
C. 90° Elbow 10 ft.
D. 45° Elbow 5 ft.
E. 90° Elbow 25 ft.
F. 45° Elbow 5 ft.
G. Roof Cap 24 ft.
OPTIONAL ACCESSORIES (AVAILABLE AT ADDITIONAL COST)
DIMENSIONS AND INSTALLATION INFORMATION (IN INCHES)

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GE JVM6175EK and is the answer not in the manual?

GE JVM6175EK Specifications

General IconGeneral
BrandGE
ModelJVM6175EK
CategoryMicrowave Oven
LanguageEnglish

Related product manuals