GE NetworX Alarm Panel Quick Guide
www.beutler.com • 1.800.435.7911 • M – F, 8:00 a . m . to 5:00 p.m. • 4700 Lang Avenue • M c Clellan, C A 95622
How to arm the system in the Away Mode.
• Close all sensors (i.e. windows and doors). The Ready indicator should be on.
• To arm, press Exit key or enter your four or six digit user code to arm the system.
• The armed icon will turn on.
• You will have _____ seconds to leave the premises.
How to arm the system in the Stay Mode.2
• Close all protected doors and windows.
• Enter your four or six digit user code.
• Press the Stay key.
How to disarm the system.
• Enter your user code to disarm the system anytime it is armed.
• If your code is not valid, the system will not disarm and a two-second error tone will sound. If this happens, try again.
How to reset the smoke detector.
• Enter *7, this will reset all smoke detectors (your system must be disarmed to use the reset function).
• If the smoke detectors have gone off, you will need to do this before you can arm the system again.
How to set the date on the keypad.
• Enter *96 followed by the master code.
• Enter the Day of Week. 1=Sunday, 2=Monday, 3=Tuesday, 4=Wednesday, 5=Thursday, 6=Friday, and 7=Saturday.
• Enter the Month Code.
01 = January 04 = April 07 = July 10 = October
02 = February 05 = May 08 = August 11 = November
03 = March 06 = June 09 = September 12 = December
• Enter the Day Code. Must always be two digits. Example: The 5
th
would be entered as 05.
• Enter the last two digits of the Year Code. Example: For 1997 enter 97.--
How to set the system clock.
• Press *97 followed by the master code.
• Enter the Hour Code which must be two digits.
12 a.m. = 00 6 a.m. = 06 12 p.m. = 12 6 p.m. = 18
1 a.m. = 01 7 a.m. = 07 1 p.m. = 13 7 p.m. = 19
2 a.m. = 02 8 a.m. = 08 2 p.m. = 14 8 p.m. = 20
3 a.m. = 03 9 a.m. = 09 3 p.m. = 15 9 p.m. = 21
4 a.m. = 04 10 a.m. = 10 4 p.m. = 16 10 p.m. = 22
5 a.m. = 05 11 a.m. = 11 5 p.m. = 17 11 p.m. = 23
• Enter the Minutes Code which must be two digits. Example: 7 minutes after would be entered 07.
How to bypass one or more zones (To turn off a selected area of the house, while still protecting the rest of the home).
• Press the Bypass key.
• Enter the zone you wish to bypass.
• Press the Bypass key again to confirm.
• Press the # key to exit the Bypass Mode.
7 8 9
*
0 #
4 5
6
1 2
3
Cancel
Stay
Chim
e
Exi
t
Bypass
Armed
Ready
FIRE
Service
Powe
r
Instant
Master Code ___ ___ ___ ___ ___ ___
Technician Name __________________________________